BREAk-In pRoCEDuRE
WARNING: Serious damage may result if the following break-in
instructions are not closely followed.
This procedure is required before the air compressor is put into
service for the first time and when the check valve or a compres-
sor pump/motor has been replaced.
1. Ensure the On/Off switch (A) is in the OFF position.
2. Plug the power cord into the correct branch circuit receptacle.
See Voltage and Circuit protection under Installation.
3. Open the drain valve (counterclockwise) fully to permit air to
escape and prevent air pressure build up in the air tank during
the break-in period.
4. Move the On/Off switch to the ON position. The compressor will
start.
5. Run the compressor for 20 minutes.
6. After 20 minutes, close the drain valve by turning clockwise.
The tank will fill to cut-out pressure and the motor will stop.
7. Compressed air will be available until it is used or bled off.
OPERATING PROCEDURES
Start-up (Fig. 1)
1. Follow pre-Start Checklist under Preparation for Use.
2. Move the On/Off switch to the ON position and allow tank pres-
sure to build. Motor will stop when tank pressure reaches
cut-out pressure.
NOTICE: Risk of unsafe operation. Compressed air from the unit
may contain wa ter condensation and oil mist. Do not spray un fil-
tered air at an item that could be damaged by moisture. Some air
op er ated tools or de vic es may require filtered air. Read the in struc-
tions for the air tool or device.
3. Adjust regulator (D) to desired setting. See Regulator under
Features.
Shut-down (Fig. 1)
1 Move On/Off switch (A) is in the OFF position. noTE: If finished
using compressor, follow Steps 2 - 6.
2. Turn regulator knob (D) counterclockwise until fully closed.
Ensure regulated pressure gauge reads 0 PSI (0 kPa).
3. Remove hose and accessory.
4. Drain the air tank, see Draining Air Tank under Maintenance.
Ensure air tank pressure gauge reads 0 PSI (0 kPa).
WARNING: Risk of bursting. Drain air tank daily. Water will con-
dense in air tank. If not drained, water will corrode and weaken the
air tank causing a risk of air tank rupture.
5. Allow the compressor to cool down.
6. Wipe air compressor clean and store in a safe, non-freezing
area.
STORAGE AND TRANSPORTING
CAUTION: Risk of property damage. In order to avoid damaging
the air compressor, do not allow the unit to be tilted more than 10º
when operating.
Place the air compressor in a clean, dry and well ventilated area
at least 12" (30.5 cm) away from the wall or other obstructions
that will interfere with the flow of air. Keep the compressor away
from areas that have dirt and/or volatile fumes in the atmosphere.
These impurities may clog the intake filter and valves, causing
inefficient operation.
The air compressor pump and shroud are designed to allow for
proper cooling. The ventilation openings on the compressor are
necessary to maintain proper operating temperature. Do not
place rags or other containers on or near these openings.
Place the air compressor on a flat surface resting on the rubber
feet.
15