When an ILDA compatible interface is connected to the laser, the laser is automatically switched to
ILDA mode. Output is then controlled from a PC running software. The scanners are set for ca.
10000 PPS at 20-25° optical, when running faster reduce image size/scan angle.

Maintenance / cleaning

Always disconnect from the mains when the device is not in use or before cleaning it.
To remove top, remove 2 screens on the top of one side plate (one front, one back), bend out side,
and slide top out. Remove any deposits of dust, especially at the fan. Check for condensed fog fluid
inside, if so, clean and rearrange the position of laser and or hazer.
"halo" is noticeable around the beam, or an unusual high amount of diffuse light can be seen inside
the
device.Clean the mirrors with window cleaner and a paper towel.
Never look directly into the light source. Always disconnect from the mains when the
device is not in use or before cleaning it.
Troubleshooting
Problem
No function / fan not working
Effects don't change to the beat of the music
Problems with DMX control
Device not working, but fan working
Laser does not switch to ILDA mode:
• The interface does not connect pins 4 and 17 (Interlock) of the IDLA signal. See interface manual
• The cable does not connect pins 4 and 17. Use a cable that connects pins 4 and 17.
• Use an adapter, that connects pins 4 and 17.
ILDA signal
Pin out of the standard ILDA signal:
1 Scanner X+
2 Scanner Y+
3 Intensity/Blanking+
4 Interlock A
5 Red+
6 Green+
7 Blue+
8 – 12 Not used
13 Shutter +5V, max. 20 mA
0..127
128..255
0..127
128..191
192..255
0..85
86..170
171.255
0..255
0..255
0..127
128..255
Possible cause
Check mains connection
Adjust sensitivity with the dial on the back.
Check if device isn't in DMX or autom. mode
Check DMX address selection
Turn device off for ca. 1 Minute.
-10V..+10V
-10V..+10V
0V..+2.5V
0..2.5V
0..2.5V
0..2.5V
Static
Dynamic (incr. Speed)
Static
Dynamic clockwise
Dynamic counterclockwise
Zoom out (incr. speed)
Zoom in (incr. speed)
Zoom in/out (incr. speed)
Size
Only points are drawn
Piecewise drawing (incr. speed)
Piecewise drawing/erasing (incr. speed)
Mirrors need cleaning, when a
14 X-
15 Y-
16 Intensity/Blanking-
17 Interlock B
18 Red-
19 Green-
20 Blue-
23-24 Not used
25 GND Signal ground
5 / 18
+10V..-10V
+10V..-10V
0..-2.5V
0..-2.5V
0..2.5V
0..-2.5V