Connection of the devices

230Vac mains power supply cable and ground – Terminals 1,2 and 3 on J1
Warning : The cable's ground pole must be connected to a good ground reference in the gate's nearby area.
Motor 1 – Terminals 4, 5 and 6 on J3
Blinker – Terminals 1 and 2 on J3
Courtesy light – Terminals 2 and 3 on J3
Electric lock – Terminals 2 and 3 on J4
Photo-cells power supply – Terminals 3 and 4 on J4
NC photo-cell contact – Terminals 9 and 12 on J4
NC stop push-button – Terminals 10 and 12 on J4
NC photostop contact – Terminals 7 and 8 on J4
NO opening start push-button – Terminals 11 and 12 on J4
NO closing start push-button – Terminals 12 and 13 on J4
NC opening limit switch – Terminals 5 and 8 on J4
NC closing limit switch – Terminals 6 and 8 on J4
Aerial – Terminals 1 and 2 on J2
Important : Before starting the gate check all connections to the electronic card. Check also the electric contacts' switching, which is
signalled by the leds' operation.
E) MAINTENANCE
Warning : The maintenance of the device must be effected only and exclusively by a specialized technician authorized from the Manufacturer.
Any operation of maintenance or control of the device must be effected in absence of power supply.
Ordinary maintenance : Every time that it is necessary and however every 6 months is recommended to verify the device operation.
Extraordinary maintenance : In case of failure, remove the device and send it for repair to the manufacturer laboratory or to authorized laboratory.
The Manufacturer is not responsible for missing observance of rules above described.