into the drain line.
NOTE: Never allow the drain hose to hang or loop higher than the floor of the ice storage bin.
3. All horizontal runs of drain lines must have a fall of
be required between the ice maker drain tube and the drain/waste receptacle. A stand
pipe with a trap below it would be acceptable for the drain/waste receptacle. A floor
drain is also acceptable. If this is not possible, Maxx Ice recommends the use of a
condensate pump. Contact Asbury Service Warranty & Parts at 1-877-368-2797.
4. Pour 1 gallon of water into the ice storage bin to check for leaks at all drain connections
and at the nut of the drain water hole. Tighten any connections or nuts that leak.
NOTE: This ice maker is not a freezer. Hot temperatures will cause a high rate of melting in the ice
storage bin.
Installation Types
This ice maker has been designed for Mobile (free-standing) installation. However, it can
also be enclosed (under a cabinet) or Built-in (sealed to the floor). In every case, there
must be adequate air space around the unit for ventilation.
Mobile installation:
A mobile installation will allow you to install the ice maker free-standing in any place you
desire provided you have access to a water supply. You must follow the stated instructions
for:
a. Electrical requirements
b. Water supply
c. Leveling the ice maker.
Enclosed Installation:
An enclosed installation will allow you to install the ice maker under a cabinet orin a
kitchen cabinet provided the required clearance space around the ice maker is respected.
This installation has the same requirements as a mobile installation.
Built-in installation:
If this method of installation is chosen, it will still be necessary to allow adequate
ventilation space around the unit. The following additional items must be observed.
1. Place ice maker in front of installation location. Remove the feet and place the unit flat
on the floor or on a platform depending on your installation requirements.
2. The water supply line must be plumbed before connecting to the ice maker.
3. The drain line must be connected. If you do not have a floor drain, you will require a
condensation pump.
4. Turn on main water supply and tap. Check for water supply connection leaks. Tighten
¼"
per foot. An air gap will likely
14