11. SpO2 measurements may be adversely affected in the presence of high ambient light. Please shield
the sensor area (e.g. with your hand or a cloth) if it is necessary.
12. Unexpected action may cause inaccurate reading.
13. Medical signal with high frequency or interference caused by a defibrillator may lead to inaccurate
reading.
14. Venous pulsations may cause inaccurate reading.
15. It may cause inaccurate reading when the positions of sensor and blood pressure cuff are on the
same arterial catheter or intravascular line.
16. Hypotension, severe vasoconstriction, severe anemia, or hypothermia may cause inaccurate
readings.
17. It may cause inaccurate reading by giving use of cardiotonic to patient after his cardiac arrest or
when he is in quiver.
18. Bright nail or painted nail may cause inaccurate SpO2 reading.
Follow local ordinances and recycling instructions regarding to disposal or recycling of the device and
device components.
Scope of Application/Intended Use
The fingertip pulse oximeter can be used to measure the human haemoglobin saturation and heart rate
through finger. It can be used in hospitals, families, schools and medical centers.
Contraindications: not found
NOTE:
1. The image in the instruction may have slight differences with the actual instruments.
2. Technical parameters and appearance change without prior notice. Product include:
mainmachine and SpO2 sensor.
Features
OLED Display: Product adopts double color OLED display, can show the six different display mode.
Low power consumption, continuously work for more than six hours with one rechargeable lithium
battery.
Battery power indicator.
In the absence of signals, the product will power-off automatically after 8 seconds.
Small in volume, light in weight, and convenient to carry.
Operation instructions
1. Plug one finger into rubber hole of the Oximeter (it is best to plug the finger thoroughly) before
releasing the clamp with the nail upwards.
2. Press button on the front panel.
3. Don't tremble your finger when the Oximeter is working. Your body is not recommended on moving
status.
4. Press the button on the front panel, if you want to change the display direction.
5. Read the relevant data from the display screen.
6. Please charge the battery in time when OLED indicates that the battery are in low power.
When plugging your finger into the Oximeter, your nail surface must be upward.
Declaration: Please use the medical alcohol to clean the rubber before each test and clean the tested
finger with alcohol before and after the test. (The rubber inside of the Oximeter adopts medical rubber,
which has no toxin, no harm, and brings no side effect such as allergy tot he skin.)
Brief description of front panel
Characteristics
OLED Display Modes
Keys function description: In standby mode, start the device into the working state. Push down the
button under working state to change the display mode. The device picture only for your reference use,
specific in kind prevail.