Show/Hide Bookmarks
6
6.1
L
Troubleshooting and fault elimination
Troubleshooting
Error messages
Call up the keypad status messages to see the last error message.
Display ( ERROR ) Error
No error
NO ERROR
Faulty data
PR ERROR
exchange
Communication
COM BROK
interrupted
RESET ERROR Communication
with system
with system
bus (CAN)
ASIC ERROR
interrupted
interrupted
SDO ERROR
Cause
-
Connection between keypad
and PC faulty
Serial data cable between
keypad and PC faulty or not
connected properly
•
Incorrect system bus wiring
(e.g. pole connection)
(e g pole connection)
•
Incorrect parameter setting
p
for interface (baud rate,
f i t f
(b d t
address, identifier)
EDBEPM-H410DE/EN/FR 3.0
( ^ 62)
Remedy
-
•
Check connection
•
Check cable
•
Check Sub D plug connection
•
Replace serial data cable
•
Check wiring ( ^ 55 )
•
•
Check parameter setting ( ^ See
Check parameter setting ( ^ See
g
"HMI Designer - Getting Started"
g
g
Manual )
M
l )
73