Télécharger Imprimer la page

Princeton Tec EOS TACTICAL MPLS Notice D'utilisation Et D'entretien

Publicité

Liens rapides

EOS
TM
TACTICAL
MPLS
Operating and Maintenance
Instructions
Notice d'utilisation et d'entretien
Bedienungsanleitung
Battery Installation – See Battery Installation Diagram
• 3 AAA
• Alkaline (LR03)
• Rechargeable NiCad or NiMH
Princeton Tec cares about the environment and
recommends recycling batteries. For more information
about battery recycling, please go to:
www.batteryrecycling.com
Observe proper battery polarity when installing the
batteries. Improper installation of the batteries will
damage the light and void the warranty.
WARNING
Never mix fresh and used batteries.
• Never mix fresh and used batteries.
• Never mix different battery brands or chemistry types.
• Always remove drained batteries immediately.
• Remove batteries during long periods of storage.
NOTE: Lithium batteries offer extended constant
brightness time, extreme cold weather performance, and
are lighter weight. Rechargeable NiCad or NiMH batteries
may result in reduced brightness due to lower nominal
voltage.
The Tactical Eos battery compartment has a waterproof
seal. It is important to keep this seal free from dirt and
away from harsh chemicals in order to preserve
waterproof integrity. Inspect the seal every time batteries
are changed. If dirt is present, wipe gently with a damp
cotton swab and mild soap until dirt is removed.
NOTE: Some battery types can emit hydrogen gas,
which can create an explosion potential in sealed
devices if it is not vented or removed. The Eos is
equipped with a platinum catalyst to remove this gas.
Upon severe impact, the catalyst could fracture. If you
notice a rattling sound in the headlamp or gray particles
in the battery compartment, do not use the headlamp.
See the warranty and return policy for more information.
Switch Operation – See Switch Operation diagram
Modes (High, medium, low, and flash) are selected by
pressing and releasing the button within 1.5 seconds of
the previous button press.
There are two ways to turn the Tactical Eos off. You can
cycle through the modes until you reach off or if more
than two seconds has passed since the previous button
press the next press of the button will turn the light off.
**The times listed on the rear of the package assume you
have start with fresh batteries and use only one mode.
NVG Mounting System
To attach the MPLS Headlamp to the NVG Shroud:
1. Slide the bracket arm into the NVG Shroud adapter
plate, making sure the pull tab is above the lip of the
adapter plate and that the male grooves on the bottom of
the bracket arm are aligned inside the female grooves on
the bottom of the adapter plate.
2. Push the bracket arm securely into place, ensuring
that the pull tab audibly clicks over the lip of the NVG
Shroud adapter plate.
3. Your MPLS Headlamp should now be secured in the
NVG Shroud. You can rotate the headlamp to focus your
light source accordingly.
To remove the MPLS headlamp from the NVG Shroud:
1. Remove the NVG Mount from your helmet.
Switch Operation
Opération de commutation
2. Push up slightly on the bottom of the light housing.
3. While pushing upward, use the tool on the provided
headstrap to press the tab of the arm bracket towards the
headlamp housing, so that it disengages from the NVG
Shroud adapter plate.
4. Slide the headlamp unit out of the NVG Shroud adapter
plate.
To attach the MPLS Headlamp to the Butterfly Mount:
1. Slide the bracket arm into the Butterfly Mount, making
sure the pull tab is above the lip of the mount and that the
male grooves on the bottom of the bracket arm are
aligned inside the female grooves on the bottom of the
mount.
2. Push the bracket arm securely into place, ensuring that
the pull tab audibly clicks over the lip of the Butterfly Mount.
3. Your MPLS Headlamp should now be secured in the
Butterfly Mount. The mount can be attached to the provided
headstrap, MOLLE straps, or any 1" webbing. You can
rotate the headlamp to focus your light source accordingly.
To remove the MPLS headlamp from the Butterfly Mount:
1. Push up slightly on the bottom of the light housing.
2. While pushing upward, use the tool on the provided
headstrap to press the tab of the arm bracket towards the
headlamp housing, so that it disengages from the Butterfly
Mount.
3. Slide the headlamp unit out of the Butterfly Mount.
Troubleshooting
If the Eos Tactical fails to light:
Check the batteries for proper installation.
Replace batteries if proper installation is confirmed.
Check the light for water contamination on the circuit
board. The light will resume normal operation once the
water is shaken or blown out and the light is left open until
completely dry. If the light has been contaminated with
salt water, flush the unit with fresh water and dry as
described above.
USA– International 5-Year Warranty
WARRANTY – Princeton Tec warrants this product to be
free from defects in workmanship and materials under
normal use for as long as you own this product. This
warranty covers all of the component parts of the product
Betriebsartenschalter
50H
10H
121H
115H
15
32
except batteries. This warranty does not cover deterioration
due to normal wear or damage due to misuse, alteration,
negligence, accidents, or unauthorized repair. Princeton Tec
will repair or replace parts which are defective in
workmanship or materials.
Your authorized Princeton Tec Dealer and Princeton Tec are
the only facilities authorized to repair the product. After (3)
unsuccessful attempts (within the warranty period) to repair
the product, you have the right to elect replacement of the
product or a refund of the purchase price less allowance for
use of the product. NO INCIDENTAL OR CONSEQUENTIAL
DAMAGES ARE INCLUDED IN THIS WARRANTY. (Some
states do not allow the exclusion or limitation of incidental or
consequential damages, so the above limitations or
exclusions may not apply to you.) This warranty gives you
specific legal rights, and you may also have other rights
which vary from state to state.
Princeton Tec reserves the right to change product
specifications without notice.
Return Policy
If your light fails to operate, follow these simple steps:
1) Check batteries. Replace if necessary.
2) Contact Princeton Tec customer service at 800-257-9080
to request an RMA number to send your light in for repair or
replacement. No warranty repairs will be accepted without
an RMA number.
3) Return the light without batteries to: Princeton Tec, 5198
Rt. 130, Bordentown, NJ 08505. Postage due and freight
collect items will not be accepted.
Princeton Tec
PO Box 8057,
Trenton, NJ 08650
Phone: 609-298-9331
Fax: 609-298-9601
www.princetontec.com
© 2021 Princeton Tec
1H
113H
100H
54

Publicité

loading

Sommaire des Matières pour Princeton Tec EOS TACTICAL MPLS

  • Page 1 Mount. 3) Return the light without batteries to: Princeton Tec, 5198 3. Slide the headlamp unit out of the Butterfly Mount. **The times listed on the rear of the package assume you Rt.
  • Page 2 1,5 seconde entre attaché à la sangle de l'appareil, appuyez sur la languette 3) Renvoyez la lampe sans piles à : Princeton Tec, 5198 Rt. de la patte de fixation vers la lampe afin de l’ôter du deux pressions.