ELECTRICAL INSTALLATION
INSTALL POWER SUPPLY AND
7
MAKE ELECTRICAL CONNECTIONS;
Fig. 9 (remote and front installation)
Ensure that the line power to bathroom
CAUTION
is OFF prior to making connections.
1. Connect Black and White power connections to AC
TRANSFORMER (1). Mount AC TRANSFORMER (1)
onto ELECTRICAL BOX (2).
2. Connect the 10' EXTENSION CABLE (sold seperately)
to the CONVERTER (7).
INSTALL ELECTRICAL BOX
8
(BY OTHERS); Fig. 10
FRONT INSTALLATION (with optional cover plate)
Note: The ELECTRICAL BOX (1) can be installed in
any location along the marked arc.
Cut a 105 x 105 mm (4-1/8" x 4-1/8") opening in finished
wall for ELECTRICAL BOX (1) (by others) and follow
installation template provided in box. See Fig. 10.
REMOTE INSTALLATION FOR POWER SUPPLY
Mount a 4" x 4" x 2-1/2" (102 x 102 x 64 mm),
ELECTRICAL BOX (1) (by others) within 10'
from the installed flush valve. See Fig. 10.
Fig.10 (TOP SPUD FIXTURE ILLUSTRATED)
Finished Wall
4
7
10'
305mm
(12" MAX.)
1
3
2
6
(51mm) 2" DIA.
HOLE FOR
CONDUIT
7
Fig. 9
2
NOTE: AC Transformer must be installed on the outside of
the Electrical Box.
8a
INSTALL CONDUIT,
ESCUTCHEON AND SENSOR
CABLE; Fig. 10
1. Drill a 2" diameter hole (shown in Fig. 10) in the finished
wall for the CONDUIT (2).
2. Pull 27" EXTENSION CABLE (3 ) through CONDUIT (2).
3. Slide ESCUTCHEON (1) onto CONDUIT (2).
4. For front installation, connect the 10' EXTENSION
CABLE (4) to the 27" EXTENSION CABLE (3). Secure
this connection with the CONNECTOR LOCKING
DEVICE (5) and place inside electrical box.
5. Slide ESCUTCHEON (1) tight against finished wall and
secure by tightening SET SCREW (6).
5
8
86mm
(3-3/8")
10' EXTENSION
7
BLACK & WHITE
1
POWER
CONNECTIONS
SMALL END
9
Electrical Box (by others) is only
required for Front Installation.
SUPPLY
(3/4" NPT)
M965645 EN REV. 2.2 (10/19)