Determine dimension y between the ends of the slide rails
11
y - 8 mm and trim
Mount cover profile onto the assembly profile
12
place. Clip on U-cover
Electrical connection: 24V DC, +15% / -10%
13
Loosen screws of the power supply unit . Remove plastic clips
Insert cover
and plastic clips
1
14
The slide rail with hold-open function is premounted for a door opening angle of 90°. The open angle can be
15
changed up to 70° by moving the hold open unit in the direction of the door middle. It can also be changed up to
130° by moving the hold open unit in the direction of the door hinges. This is achieved by opening the door until
the requested opening angle is achieved and fixing it in this position. In order to move the hold open unit, you
have to loosen the fixing screw
fixing screw . In case the max. door opening angle is smaller than 90°, the sliding block might cover the fixing
1
screw. In this case, the hold-open unit has to be moved till dead stop in direction of door middle after fixing
screw has been loosened. This has to be done before the door is opened and fixed in wished position. Tighten
fixing screw and adjust (as described above) the requested hold-open angle.
Carry out a functionality test of hold-open function.
Clip the screw hole cover into the passive leaf slide rail.
16
. Connect connection cable
2
4
and pignon cover
5
1
. Adjust covers and fix into place
2
. Move the hold-open unit till dead stop of the sliding block and tighten the
1
. Cut cover profile to length in line with dimension
1
3
.
1
and attach plastic clips
onto the door closer.
and cover
2
3
2
. Adjust cover profile
3
. Connect to power supply
.
and fix in
3
.
4
12/14