Page 1
WarmlyYours sells this product under part number SCE-120. The control’s manufacturer identifies this same part with the model number of ETO2 in all the documentation provided with the control. If you have any technical questions related to this control or the installation of any of our radiant heating systems, please call our 24/7 installation team at (800) 875-5285 or visit our website at www.WarmlyYours.com.
Page 2
Type ETO2 Controller for ice and snow melting English Français GREEN COMFORT Maximum comfort with low energy consumption...
Page 7
3. The output relay for the heating cable in the zone concerned Products marked with this symbol must not be should activate and ON should be indicated on the ETO2 disposed of along with household refuse, but must be display. Check that the heating cable becomes warm, check delivered to a waste collection centre in accordance the voltage if possible.
L’ETO2 L’alimentation doit être débranchée avant toutes interventions est adéquat pour contrôler des câbles chauffants électriques et d’installation ou d’entretien de cet appareil et ses composants.
An easily operated encoder button and backlit graphic display ensure quick and easy configuration and simple indication of temperature, status, etc. ETO2 is suitable for controlling electric heating cables in 1 or 2 zones. It also features advanced two-stage output control for economic operation.
STARTUP When ETO2 is switched on for the first time, Celsius or Fahrenheit must be selected. Turn the encoder button SELECT SCALE: until the required temperature scale is highlighted. Then accept the selection by pressing the encoder button.
OPERATION ETO2 is equipped with an easily operated encoder button (turn and press) and a display which describes the current situation. The display is backlit and is illuminated by pressing the encoder button (OK). The illumination is automatically switched off after 30 seconds.
Manual start of forced heating. Press OK and select ON to start forced heating. FORCE HEAT The ETO2 controller will provide heat for the pre-programmed afterrun time, see AFTERRUN 1 and 2. Whether temperature is to be displayed in Celsius (C) or Fahrenheit (F) can be selected here. Select the SELECT SCALE required scale and press OK.
Page 18
AFTERRUN 2 2:00 button to set the required afterrun time and press OK. Zone 1 temperature can be calibrated here. With the ETOG-55 sensor, the temperature shown on the ETO2 OFFSET T1 0.0C display is always the core temperature of the sensor. For calibration, please see OFFSET CALIBRATION.
Select this option and press OK to return to the main menu. EXIT RESTART After changing the settings, or whenever a new process start is required, the ETO2 can be restarted in this menu. Restarts operation while retaining all your current settings. The ETO2 goes to the initial status display. RESTART...
TROUBLESHOOTING If faults occur in the ice and snow melting system, it is advisable to check the ETO2 setup. Activate the menu by pressing the encoder button and select SHOW INFO to display the application settings. If there are errors in the setup, activate REINSTALL using factory code 1202.
INTRODUCTION Le type ETO2 est un contrôleur électronique pour la fonte totalement automatique et économique de la glace et la neige sur les surfaces extérieures et dans les gouttières. La glace se forme en cas de basses températures et d’humidité. ETO2 détecte autant la température que l’humidité...
à la valeur requise. DÉMARRAGE Quand ETO2 est mis sous tension pour la première fois, il faut choisir entre Celsius ou Fahrenheit. Tournez le SELECT SCALE: bouton de l’encodeur jusqu'à ce que l’échelle de température requise soit en surbrillance. Puis appuyez sur le CELSIUS bouton de l’encodeur pour confirmer le choix.
FONCTIONNEMENT ETO2 est muni d’un bouton pour l’encodeur qui est facile d’utilisation (tourner et appuyer) ainsi que d’un afficheur qui décrit la situation actuelle. L’afficheur est rétroéclairé et il s’allume en appuyant sur le bouton de l’encodeur (OK). L’afficheur s’éteint automatiquement après 30 secondes.
Démarrage manuel ou chauffage forcé. Appuyez sur OK et sélectionnes ON pour démarrer le chauffage FORCE HEAT forcé. Le contrôleur ETO2 fournira la chaleur pour la période de post-chauffage qui est préprogrammé, voir POST- CHAUFFAGE 1 et 2. Ici vous pouvez choisir l’affichage de la température en Celsius (C) ou Fahrenheit (F). Sélectionnez l’échelle SELECT SCALE appropriée puis appuyez sur OK.
Page 26
OFFSET T1 0.0C de l'ETO2 est toujours celle du centre de la sonde. Pour la calibration, veuillez vous référer à CALIBRATION D’OFFSET. La température de zone 2 peut être calibrée ici. Avec la sonde ETOG-55, la température affichée sur l'écran OFFSET T2 0.0C...
EXIT REDÉMARRAGE Après un changement des réglages ou toutes les fois qu'un nouveau démarrage de procédé est requis, l'ETO2 peut être redémarré dans ce menu. Redémarrage de l'opération en maintenant vos réglages actuels. L'ETO2 passe à l'affichage de l'état initial.
RECHERCHE DE PANNES Si une faute apparaît dans le système de fonte de glace et de neige, il est recommandé de vérifier le réglage de l'ETO2. Accédez au menu en appuyant sur le bouton de l'encodeur et sélectionnez « SHOW INFO » pour afficher les réglages de l'application. S’il y a des erreurs dans le réglage, activer « REINSTALL »...