Resistance
Meas. Range
200 V
2 kV
20 kV
200 kV
2000 kV
Diode Test
Display of forward voltage
Test current 1 mA approx. · Open circuit voltage 3 V approx.
Continuity Test
Signal sound if resistance value smaller than 300 V approx.
Open circuit voltage 2.5 V approx..
Model 9005: Measurement Ranges
DC Voltage
Meas. Range
320 mV
3.2 V
32 V
320 V
600 V
AC Voltage (50 ... 400 Hz)
Meas. Range
3.2 V
32 V
320 V
600 V
DC Current
Meas. Range
320 µA
3200 µA
32 mA
320 mA
15 A
Input current 10 ... 15 A for a maximum of 15 seconds
AC Current (50 ... 400 Hz)
Meas. Range
320 µA
3200 µA
32 mA
320 mA
15 A
Input current 10 ... 15 A for a maximum of 15 seconds
22
Accuracy
Resolution
0.1 V
1.0 V
% (0.8 % rdg
10 V
+ 2 digits)
100 V
1 kV
Accuracy
Resolution
0.1 mV
1.0 mV
% (0.5 % rdg
10 mV
+ 2 digits)
100 mV
1 V
Accuracy
Resolution
1.0 mV
% (1 % rdg
10 mV
100 mV
+ 5 digits)
1 V
Accuracy
Resolution
0.1 µA
1 µA
% (1.0 % rdg + 2 digits)
10 µA
100 µA
10 mA
% (2.0 % rdg + 2 digits)
Accuracy
Resolution
0.1 µA
1 µA
% (1.5 % rdg + 3 digits)
10 µA
100 µA
10 mA
% (2 % rdg + 3 digits)
Open Circuit
Overload prot.
Voltage
250 V
< 3 V
AC/DC
Input-
Overload prot.
Resistance
5 MV*/
600 V
10 MV
AC/DC
Input-
Overload prot.
Resistance
5 MV*/
600 V
10 MV
AC/DC
Load-
Overlaod prot.
Voltage
1,6 V
500 mA/250 V
75 mV
12,5 A/250 V
Load-
Overload prot.
Voltage
500 mA/250 V
1,6 V
75 mV
12,5 A/250 V
* Auto AC/DC
* Auto AC/DC

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Unitest 9005

Table des Matières