Fuse Replacement; Technical Characteristics - BEHA Unitest 9004 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Model 9004:
Model 9005:
Respect correct polarity !
5. Close battery case and continue measurements.
Please consider our environment when disposing of used batteries.
They belong in a rubbish dump for hazardous waste.
If the instruments are not in use for a long period of time, the batteries
have to be removed.
Should it happen that due to leaking batteries the instrument becomes
soiled, the multimeters have sent back to plant for cleaning and
checking.
Please, comply with the respective valid regulation regarding the
return, recycling and disposal of used batteries and accumulators.

5.2 Fuse Replacement

If the fuse has tripped due to current range overload, please respect
the following references for fuse replacement.
Only use fuses with sepcified current and voltage values, switch-off
characteristics and capacities.
1. Remove instrument from all circuits.
2. Remove test leads and switch off instrument.
3. Remove the protective rubber holster and open battery case on the
rear of the instrument. Loosen the 4 screws.
4. Remove defective fuse.
5. Insert new fuse ensuring it is positioned correctly.
Model 9004
200 mA / 250 V, Quick Blow
for 200 mA Current Range
12,5 A/250 V, quick below,
switch off capacity 6000 A
for 15 A current range
Using auxiliary fuses and short-circuiting the fuse holders is prohi-
bited and can lead to instrument destruction and serious personnel
injury.
Spare fuses are available at every salesman.

6.0 Technical Characteristics

Display:
Measuring Rate:
Overload Display: "1" appears left
20
1 pc 9 V battery IEC 6LR61
2 pcs 1.5 V batteries IEC LR6
Model 9004
3
/
digit, LCD Display 3
1
2
1999 Digits
Polarity Display, HV
Battery
2.5 meas./s approx.
Model 9005
500 mA/250 V, Quick Blow
for 320 mA Current Range
12,5 A/250 V, quick blow, switch
off capacity 6000 A
for 15 A current range
Model 9005
/
3
4
3260 Digits, Analogue
Bargraph Display, Polari-
ty Display, AC/DC, Units,
Battery
2.5 meas./s approx
"OL" appears on display
digit, LCD Display