The waste disposal cooler should not be placed in direct sunlight!
1.
The cooler should be installed on a level surface.
2.
After installation, leave the waste disposal cooler standing for no less than two hours before switching
on to avoid damaging the compressor. Refrigerant: R134a.
3.
Voltage: 220‑240 V / 470 Watt. Don't forget to earth.
4.
For an optimum temperature, install the cooler in a position where adequate air circulation is
guaranteed.
5.
Clean the condenser at least once a month by means of a vacuum cleaner or compressed air.
6.
The temperature in the waste disposal cooler can be adjusted by the thermostat knob. As standard, this
thermostat is set at about +4°C.
7.
The ideal temperature is depedent upon the quantity and temperature of the products to be cooled and
is also affected by the ambient temperature.
8.
Don't place heavy objects on the cover plate.
General
For all actions in machinery or electric parts: ensure the plug is disconnected from the mains.
It is possible that sharp parts appear in the engine room. Be careful if you have to do operations
in the engine room. It is possible that parts in the engine room are very hot (90°C). Convince
yourself that all parts are chilled enough before you do operations in the engine room. Always
mount eventual removed grids and/or other parts on the same place as before.