INSTALLATION INSTRUCTIONS
Thermostat
STEP 3
For best results, use a Cadet electronic wall thermostat or an EBKN double pole thermostat kit. It is recom-
mended that a thermostat be provided for each room. The location of the wall thermostat should be selected
carefully. Thermostats should not be located near drafts from an open doorway or within 18" (45.7cm) of an
outside wall, or in direct sunlight or unusual heat sources. A television set or appliance that builds up heat near
a thermostat will prevent the thermostat from functioning properly. A wiring diagram illustrating typical wiring of
the thermostat is included in the literature provided with the thermostat.
Illustrated in Figures 8 through 12 are wiring diagrams typical of a single unit controlled by a single pole ther-
mostat, a single unit controlled by a double pole thermostat, and two units controlled by a double pole thermo-
stat.
Single Pole
Single Pole
Thermostat
Thermostat
Single Pole
Single Pole
Thermostat
Thermostat
Single Pole Wall Thermostat Left End Wiring
Figure 8
Single Pole
Thermostat
Figure 10
Double Pole Wall Thermostat Left End Wiring
STEP 4
Reassemble
Tuck wires into wiring compartment cover, and replace one screw previously removed. Replace front heater
cover.
Page 4
120, 240 or 208 volt models
240 or 208 volt models only
(continued)
Single Pole Wall Thermostat Right End Wiring
Figure 9
Single Pole
Thermostat
Figure 11
Double Pole Wall Thermostat Right End Wiring
Single Pole
Single Pole
Thermostat
Thermostat
Single Pole
Single Pole
Thermostat
Thermostat
120, 240 or 208 volt models
240 or 208 volt models only
Figure 12
Connecting
Multiple
Units
Left End
Wiring
240 or 208
volt models
only