Remove the plugs (1) from the pump (2) by
using a screwdriver.
3
Fix the bracket (3) supplied with tilt X52 to the
dashboard (4) by following the instructions
enclosed to tilt X52.
4
Screw the nuts completely on the
corresponding 90° unions (3), Fit and screw the
unions manually as indicated in the picture until
they are inserted completely. Turn them until
they are positioned correctly with respect to the
pipes by unscrewing them no more than one
revolution, then tighten the nuts with a 11/16"
Allen wrench with a torque of 17,6 Nm (13 lb ft)
until the washer touches the nut.
WARNING
DO NOT USE teflon tape or adhesive tape.
DO NOT PUT any thread sealant like Loctite 542
or similar products.