DIMENSIONS AND SPECIFICATIONS
Gas Pressures
GAS
Natural
Propane
Individual Burner Input Rates
Open Burner
Hot Top,
12" Griddle,
Broiler/Griddle
26" Oven Burner Standard or RC
20" Oven Burner
Models Designations
MODEL NO.
SX-4
SX-4-20
SX-6
SX-6-26
SX-6-24BG-2626
SX-6-24BG-26
SX-10-2626
SX-10-26
SX-1HT-4
SX-1HT-4-26
SX-24G-2
SX-24G-2-26
SX-24G-6-26
SX-24G-6-2626
Page 4
MINIMUM SUPPLY GAS PRESSURE
7" WC
11" WC
BURNER
(4) Open Burners, Storage Base
(4) Open Burners, (1) 20" Oven
(6) Open Burners, Storage Base
(6) Open Burners, (1) 26" Oven
(6) Open Burners, (1) 24" Raised Broiler/Griddle, (2) 26" Ovens
(6) Open Burners, (1) 24" Raised Broiler/Griddle, (1) 26" Oven (1) Storage Base
(10) Open Burners, (2) 26" Ovens
(10) Open Burners, (1) 26" Oven (1) Storage Base
(4) Open Burners, (1) 12" Hot Top, (1) Storage Base
(4) Open Burners, (1) 12" Hot Top, (1) 26" Oven
(2) Open Burners, (1) 24" Griddle, (1) Storage Base
(2) Open Burners, (1) 24" Griddle, (1) 26" Oven
(6) Open Burners (1) 24" Griddle, (1) 26" Oven, (1) Storage Base
(6) Open Burners (1) 24" Griddle, (2) 26" Ovens
MANIFOLD OPERATING PRESSURE
17.5 mbar
27.5 mbar
NATURAL GAS
INPUT
ORIFICE
BTU/HR
SIZE DMS
28,000
#39
20,000
#45
20,000
#45
14,000
#52
30,000
#36
25,000
#40
DESCRIPTION
4.5" WC
11.25 mbar
10.0"WC
25 mbar
PROPANE GAS
INPUT
ORIFICE
BTU/HR
SIZE DMS
28,000
1.5 mm
20,000
#54
20,000
#54
13,500
#57
30,000
#51
25,000
#54
Part # 4515146 (02/29/08)