Wiring the Relay Output
The relay output alarm contacts are in the middle of the
terminal block connector as shown in the figure.
By inserting the wires and set the DIP switch to "ON", relay
output alarm will detect any port failures, and form a short
circuit. The alarm relay output is "Normal Open".

Connecting to Network

1. Connecting the Ethernet Ports: Connect one end of an Ethernet cable into the UTP port of
SDI-550/541, while the other end is connected to the attached networking device. All UTP ports
support auto MDI/MDIX function. The LNK / ACT LED will turn Yellow for 10M Ethernet or Green
for 100M Ethernet.
2. Connecting the Fiber Port (SDI-541) : Connect the fiber port on your SDI-541
to another Fiber Ethernet device, by following the figure below.
Wrong connection will cause the fiber port not working properly.
ATTENTION
DIP Switch Settings for Alarm Relay Output
Pin No. #
Status
P1 to P5
(Pin1 ~5)
This is a Class 1 Laser/LED product.
Don't stare into the Laser/LED Beam.
Description
ON
To enable port break alarm at this port.
Off
To disable port break alarm at this port.
Alarm
V+
V-
Relay Output,
Carry ability 1A @24V
TX
TX
RX
RX
Cable Wiring(SC to SC)
TX A
RX A
Alarm Switch
RX B
TX B