Instructions for installation and use – only for experts
P. 4/10
2. Instructions for installation
CAUTION: all packaging components must be removed before commissioning
The infrared radiator must only be installed on the cabin ceiling, at a height which is not easily reachable,
min. 1.8m. Ensure that the reverse of the radiator is not covered and that the generated heat can escape!
Installation into the cabin wall is not permitted.
If the infrared radiator is installed in the back region, it must be ensured by means of a suitable protective
measure that the protective grille or front glass panel cannot be inadvertently depressed.
Ensure compliance with minimum distances.
The supplied fire protection tape must be applied.
The glass plate of the radiator can become very hot. The radiator may only be installed at a height which
is not easily reachable (>1.8m)
An optional screen VIT-BL-L stainless steel screen for IR radiators
(500W/750W/1300W) is available for spray water-protected installation in accordance with IPX4
A minimum distance of 150 mm must be complied with between the radiators.
There must be at least 300mm of free, well ventilated space above the radiator.
If the radiator is installed in the field of vision, a minimum distance of 1300mm must be complied with bet-
ween the face of the user and the radiator surface.