5.4 Possible anomalies
ANOMALY
The machine does
not start
The spiral turns
incostantly
The machine stops
while working

CHAPTER 6 DEMOLITION OF THE MACHINE

In case of dismantelling and demolition of the machine, the pieces which the machine is
made of, do not present any kind of danger that necessitates any particular caution.
To facilitate the recycling process of the materials, you must separate all electrical
components.
SPIRAL MIXER - iM Series Operating manual
CAUSE
· Lack of energy in the
power grid
· The Emergency stop button
in blocked
· The protection grid
and/or the top are up
· The knob of the general
switch is in position 0
· The knob of the speed
selector is in position 0
· The timer is in position 0
· The chain is loose
· Stop of the fuse
SOLUTION
· Check the general switch,
the plug, the tap and the
feeding cable
· Rotate the button following
the direction of the arrow
· Put down correctly both
the grid and the top
· Rotate the knob in position 1
· Rotate the knob in position
1 or 2
· Rotate the knob of the timer
from 1 to 30 minutes
· Stretch the chain following
the instructions at par. 5.2
· Change the fuse with
another on which has the
same characteristics