PROGRAMMING MYQ
To Program MyQ Devices:
1. To enter programming mode, press and release the RADIO button
on the logic board (the RADIO LED will light).
2. To program the MyQ device, place the MyQ device into learn
mode (see instructions for the specific MyQ device).
3. When the programming is complete the RADIO LED will turn off.
NOTE: If the programming is not completed within 3 minutes, the
program mode will be exited and the RADIO LED will turn off.
To Erase All MyQ Devices:
1. Press and release the RADIO button on the logic board (the
RADIO LED will light).
MAINTENANCE ALERT SYSTEM (MAS)
Feature: An internal cycle counter will activate a flashing LED on the
3-button control station when the preset number of cycles or months
has elapsed (whichever occurs first). Setting this feature is optional.
By default this feature will never activate. Logic 5 operators
incorporate a self diagnostic feature built into the MAS LED. In
addition to indicating when routine maintenance is due, the MAS
LED can be used to troubleshoot some problems with the operator.
Benefit: The Maintenance Alert System (MAS) assists the installing
dealer in setting up a routine maintenance program. Once
programmed, the MAS notifies the end user (with a flashing LED on
the 3-button station) when a preset number of cycles/months has
elapsed and scheduled maintenance is due.
To Program:
1. Close the door.
2. Turn the selector dial to PROGRAM.
3. Press and release the MAS SET button.
4. Press the STOP button once to clear the MAS memory.
5. Press the OPEN button once for every 5,000 cycles increments.
Press the CLOSE button once for every 3 month increments.
6. Press and release the MAS button to complete the programming.
The on board LED will flash back the programmed settings. The
OPEN LED will flash once for every 5,000 cycles. The CLOSE LED
will flash once for every 3 months.
7. Turn the selector dial back to the desired wiring type.
NOTE: If MAS LED flashes 2 or more flashes in a row followed by a
pause, an operator error occurred. Turn to page 10 to diagnose
problem.
Example: A door is installed with 30,000 cycle springs and has an
annual service contract. To set the MAS, turn selector dial to
PROGRAM, press MAS button, press the STOP button to clear the
memory and then press the OPEN button 6 times (30,000 cycles)
and CLOSE 4 times (12 months). Press the MAS again to complete
the programming. Turn the selector dial back to desired wiring type.
Special Notes about MAS: A 5th wire must be run to the control
station to activate the MAS LED. The MAS LED on the logic board is
always enabled. When the operator is serviced after the MAS LED
has started to flash, repeat the setup procedure to program in the
number or cycles desired until the next service visit OR press and
hold the MAS button for 5 seconds in the PROGRAM mode to reset
the MAS with its current programmed value. To disable the MAS,
follow the programming procedure above and press the STOP button
to reset the counter to zero. Every time the operator leaves the close
limit is counted as one cycle.
To view how many cycles are programmed into the MAS, set the
selector dial to DIAGNOSTIC and press the MAS button. The OPEN
button LED will flash once for every 5,000 cycle increment
programmed and the CLOSE button LED will flash once for every 3
®
DEVICES (OPTIONAL)
2. Press and hold the MAS button for 5 seconds. The RADIO LED
will flash for approximately 5 seconds and the RADIO LED will
turn off.
All MyQ devices are now erased.
To Erase One MyQ Device:
1. See instructions for the specific MyQ device to erase the
programming.
2. When the erase is complete, the MyQ device will be erased on the
operator. The operator does not need to be reprogrammed to
erase the MyQ device.
NOTE: Power the operator to complete the erase operation.
month increment programmed.
To view how many cycles have elapsed since the last time the MAS
was programmed, set the selector dial to DIAGNOSTIC and press
the MAS button. Press the OPEN button; the OPEN LED will flash
once for every 5,000 cycles that has elapsed. Press the CLOSE
button; the CLOSE LED will flash once for every (3) months that has
elapsed. Press the MAS button to exit. Turn the selector dial back to
desired wiring type.
Operation will vary
depending on wiring
type
3-BUTTON CONTROL STATION
Maintenance Alert LED
Press This
OPEN
Adds 5,000 cycles to Maintenance Alert
System Activation Counter.
Adds 3 Months to Maintenance Alert System
CLOSE
Activation Timer.
STOP
Clears memory, sets Maintenance Alert
System Activation Counter to 0 cycles and
0 months.
6
SELECTOR DIAL
T
TS
E2
FSTS
D1
DIAG
OPTN
C2
B2
PROG
T
TS
E2
FSTS
D1
DIAG
OPTN
C2
B2
PROG
OPEN
CLOSE
STOP
To Get This