Installation to Concrete Wall
• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
• Make sure that the supporting surface will safely support the combined load of the equipment and all attached
hardware and components.
• Never exceed the Maximum UL Load Capacity of 175 lb (79 kg).
• Never mount this product to metal studs.
IMPORTANT! Concrete must be 2000 psi density minimum.
Use wall plate (A), making sure that it is level, as a
1
template to mark holes. The top mounting slots should
be located .36" above the desired screen center for PLA
60-UNL, PLA 60-UNL-S, PLA 60-UNLP, RTPLA 60, PLA
60-UNLP-S and RTPLA 60-S and .43" below the desired
screen center for PLAV 60-UNL, PLAV 60-UNL-S, PLAV
60-UNLP , PLAV 60-UNLP-S, RTPLA UN7, RTPLA
UN7S, D-FPA-320 and D-FPA-320S. Use the masonry
bit to drill 5/16" (8 mm) dia. holes to a minimum depth of
3" (76 mm). Insert anchors (W) in holes flush with wall as
shown (right). Place wall plate (A) over anchors (W) and
secure with 5/16 x 3" wood screws (O) and washers (P).
WARNING
• Tighten wood screws so that wall plate is firmly
attached, but do not overtighten. Overtightening can
damage screws, greatly reducing their holding power.
• Never tighten in excess of 80 in • lb (9 N.M.).
WARNING
• Always attach concrete expansion anchors directly to
load-bearing concrete.
• Never attach concrete expansion anchors to concrete
covered with plaster, drywall, or other finishing mate-
rial. If mounting to concrete surfaces covered with a
finishing surface is unavoidable, the finishing surface
must be counterbored as shown below. If plaster/
drywall is thicker than 5/8", custom fasteners must be
supplied by installer (Not evaluated by UL).
1-4
INCORRECT
mounting
plate
plaster/
dry wall
WARNING
CORRECT
mounting
concrete
plate
plaster/
dry wall
1-1
Drill hole(s) and insert anchor(s) (W)
1-2
Place plate over anchor(s) (W) and secure with screw(s)(O)
1-3
Tighten all fasteners
P
O
concrete
7 of 42
mounting
plate
W
A