Long Term Storage Of Your Heater - Dyna-Glo Delux SF70DGD Guide D'utilisation Et Instructions De Fonctionnement

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
CAUTION : Do not disconnect the power source or unplug the power cord until the cooling cycle has
TO RESTART THE HEATER
1.Wait 10 seconds after cooling cycle has completed.
2. Turn the Operating Switch to "ON" position.
3. Be sure to follow all starting procedure precautions.
CAUTION : DO NOT operate heater without heat shield assembled to the heater.
CAUTION : NEVER use an accessory thermostat with this heater.

8. LONG TERM STORAGE OF YOUR HEATER

• Remove Fuel Cap and Fuel Cap Filter.
• Remove Kerosene from the tank by using an approved siphon pump
and wash Fuel Cap Filter with clean kerosene.
• Rinse and swirl the kerosene inside the fuel tank by using a small amount of kerosene.
• Make sure the tank is completely empty.
Never leave kerosene in the tank over a long period time because using old kerosene can damage the heater.
Store heater in a dry, well-ventilated area
• Be sure that the storage area is free of dust and corrosive vapors. Repack the original shipping material.
keep the User's Manual in an easily accessible place.
9. MAINTENANCE
WARNING!! : NEVER SERVICE HEATER WHILE IT IS PLUGGED IN OR
USE ORIGINAL EQUIPMENT REPLACEMENT PARTS.
Use of third party or other alternate components
will void warranty and may cause unsafe operating
conditions.
A) BACK COVER REMOVAL
1) Remove 4 Screws along circumference of the Back Cover.
2) Disconnect Operating Switch Wire and Display PCB
wire from PCB Board.
3) Remove Back Cover.
B) FUEL TANK
Flush every 200 hours of operation or as needed
(See above,8.Long term storage of your heater)
been completed!
Temperature of the floor is hot while in operation. Use the heater without heater shield,
will cause deformation or discoloration of the floor.
Accessory thermostat will bypass the cooling cycle after the heater is shuts off
and damage the heater.
WHILE HOT!
Operating Switch
wire
Figure 4. Back Cover Removal
7
Screw
Back Cover
Display PCB
wire

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Pro sf70h

Table des Matières