Maintenance And Cleaning - Binzel Abicor iSTM Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

iSTM

9 Maintenance and cleaning

Scheduled maintenance and cleaning is a prerequisite for a long life and a trouble-free
operation. In doing so, observe the following:
DANGER
Risk of injury due to unexpected start-up.
Improper operation can lead to serious injuries that could result in death.
For the entire duration of maintenance, servicing, dismounting and repair work, the following
instructions must be adhered to:
• Switch off the power source.
• Close the gas supply.
• Close off the compressed air supply.
• Close off the coolant supply.
• Disconnect all electrical connections.
• Switch off the entire welding system.
DANGER
Electric shock
Dangerous voltage due to defective cables.
• Check all live cables and connections for proper installation.
• Replace any damaged, deformed or worn parts.
NOTICE
• The maintenance intervals given are standard values and refer to single-shift operation.
• Only qualified personnel are permitted to perform work on the device or system.
• Always wear your personal protective clothing when performing maintenance and
cleaning work.
9.1 iSTM Cleaning the ABIROB
1
1
Covering ring
Fig. 11
BAL.0150 • 2020-08-03
®
A
2
4
2
2 set screws
iSTM Cleaning the ABIROB
9 Maintenance and cleaning
3
®
3
ABIROB
A iSTM mount
®
A
4
O-ring
EN - 17