AERMEC DUALCHILLER CONTROL Installation Et Emploi page 17

Accessoires
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

100
RS 3
101
RS 4
102
VSL 1
103
VSL 2
104
VSL 3
105
VSL 4
106
VREC 1
107
VREC 2
108
VREC 3
109
VREC 4
110
VB 1
111
VB 2
112
VB 3
113
VB 4
114
VR 1
115
VR 2
116
VR 3
117
VR 4
118
RI 1 (Master)
119
RI 2 (Master)
120
RI 3 (Master)
121
RI 1 (Slave)
122
RI 2 (Slave)
123
RI 3 (Slave)
124
V3VFC (Master)
125
V3VFC (Slave)
126
VA 1
127
VA 2
128
VA 3
129
VA 4
130
VB 1
131
VB 2
132
VB 3
133
VB 4
134
VAA 1
135
VAA 2
136
VAA 3
137
VAA 4
138
VBB 1
139
VBB 2
140
VBB 3
141
VBB 4
141
Global alarm summary
142
Probe B4
143
Probe B5
7. 1
WRITE DIGITAL DATA
ADDRESS
DATA ITEM
145
On / Off
146
Cold/Hot
147
Reset
Status of circuit 3 antifreeze resistence output
Status of circuit 4 antifreeze resistence output
Status of circuit 1 fluid solenoid valve output
Status of circuit 2 fluid solenoid valve output
Status of circuit 3 fluid solenoid valve output
Status of circuit 4 fluid solenoid valve output
Status of circuit 1 3-way recovery valve output
Status of circuit 2 3-way recovery valve output
Status of circuit 3 3-way recovery valve output
Status of circuit 4 3-way recovery valve output
Status of circuit 1 VB recovery valve output
Status of circuit 2 VB recovery valve output
Status of circuit 3 VB recovery valve output
Status of circuit 4 VB recovery valve output
Status of circuit 1 VR recovery valve output
Status of circuit 2 VR recovery valve output
Status of circuit 3 VR recovery valve output
Status of circuit 4 VR recovery valve output
Status of MASTER integration resistence 1 output
Status of MASTER integration resistence 2 output
Status of MASTER integration resistence 3 output
Status of SLAVE integration resistence 1 output
Status of SLAVE integration resistence 2 output
Status of SLAVE integration resistence 3 output
Status of MASTER 3-way freecooling valve output
Status of SLAVE 3-way freecooling valve output
Status of circuit 1 VA freecooling valve output
Status of circuit 2 VA freecooling valve output
Status of circuit 3 VA freecooling valve output
Status of circuit 4 VA freecooling valve output
Status of circuit 1 VB freecooling valve output
Status of circuit 2 VB freecooling valve output
Status of circuit 3 VB freecooling valve output
Status of circuit 4 VB freecooling valve output
Status of circuit 1 VAA freecooling valve output
Status of circuit 2 VAA freecooling valve output
Status of circuit 3 VAA freecooling valve output
Status of circuit 4 VAA freecooling valve output
Status of circuit 1 VBB freecooling valve output
Status of circuit 2 VBB freecooling valve output
Status of circuit 3 VBB freecooling valve output
Status of circuit 1 VBB freecooling valve output
Global alarm summary
B4 probes faulty or missing
B5 probes faulty or missing
DESCRIPTION
Off = 0 ; On = 1
Cold = 0; Hot = 1;
Alarm Reset 1 = reset
17

Publicité

Table des Matières
loading

Table des Matières