3.1 CONTROL PANEL
The machines belonging to this series are provided with an electronic system for parameters modification, so eventual
reset operations can be performed by means of the digital panel located on the front of the dryer.
The control panel is composed of 5 keys (ON/OFF, TEST, SET, DOWN e UP) and a 3 digit display, with three
signalling LEDs shown as DP1, DP2 and DP3.
Under normal operating conditions the display controller shows the temperature read by the probe without decimal
degrees. When an alarm condition occurs, the display shows the relevant alarm code.
DISPLAY VISUALIZATION AND SIGNALLING LEDS (Mod. 10 ÷ 320)
DISPLAY
the unit is ON with low load
the unit is ON with normal load
the unit is ON with normal-high load
the unit is ON with high load
ON/OFF
Cod. 710.0138.20.00 Rev1A – 10.2010
3. START UP
DESCRIPTION
ON-OFF
STATUS
LED
ON
DP1
Blinking
Programming mode activated
DP2
ON
ON
DP3
Blinking
OFF
TEST
SET
UP
DOWN
ENGLISH
ASD 10 - 320
PIC. 1 -
DESCRIPTION
Compressor energized
Condensate drain energized
Speed of the fan = 100%
Speed of the fan < 100%
Fan not running
Pic.2 - ASD 400 - 600
6 - 46