DV Systems ASD10 Manuel D'instructions Et D'entretien page 43

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

AIR DRYER DATA SHEET – PLAQUETA TÉCNICA SECADOR –
CARACTERISTIQUES TECHNIQUES SÉCHEUR
Air flow rate*
Caudal*
Nom. consumption
Consumo nom.
Full load consumpt.
Consumo max
Nom. Current
Absorciòn nom.
Full load current
Absorciòn piena car.
Locked rotor current
Absorciòn principio
Power supply
Alimentaciòn
Fan motor current
Absorciòn nom. ventilador
Fan motor power supply
Alimentaciòn ventilador
Air connections
Uniones de aire
Refrigerant
Refrigerante
Weight
Peso
Air inlet temperature
Temp.aire en entrada
Ambient temperature
Temp. ambiente
Working pressure
Press. nominal
Pressure dew point
Punto de rocío
Sound pressure level
Nivel de presión sonora
*Rating conditions of: 38°C (100°F) and 100 psig Air Inlet, 38°C Ambient,
and 3°C (38°F) Leaving Dew Point.
Prestazioni e dati tecnici – Performance and specifications – Leistungen und technische
Prestaciones y datos técnicos – Performances et caractéristiques techniques
Cod. 710.0138.20.00 Rev1A – 10.2010
Performances*
Consommation nom.
Cons. pleine charge
Ampere nominale
Ampere pl. charge
Ampere max.
Alimentation
Ampere nominale ventilateur
Ventilateur alimentation
Connexion air comp.
Réfrigérant
Poids
Temp. entrée d'air
Temp. ambiante
Pression travail
Press.pt de rosée
Niveau de pression
acoustique
ASD10
m3/h
17
CFM
10
KW
0.16
KW
0.22
A
1.89
A
2.21
A
18
V/Ph/Hz
115/1/60
A
0,58
V/Ph/Hz
115/1/60
-
3/8"
type
R134a
Kg
18
Lb
39.7
°C
38 (Max 50)
F
100 (Max 120)
°C
38 (Max 40)
F
100 (Max 104)
Bar
7 (Max 16)
PSI
100 (Max 232)
°C
0,5 – 4
F
33 – 39
dB(A)
< 70
( C )
ASD15
25
15
0.16
0.22
1.89
2.21
18
115/1/60
0,58
115/1/60
3/8"
R134a
18
39.7
38 (Max 50)
100 (Max 120)
38 (Max 40)
100 (Max 104)
7 (Max 16)
100 (Max 232)
0,5 – 4
33 – 39
+ / - 5%
42 - 46