Introduction
Dear customer!
Thank you for buying one of our products.
You can find all the information you need in these operating instructions.
Please read the instructions completely with care and observe the advice given.
The operating instructions are part of the Digital cylinder leakage test kit and should be kept intact.
The manufacturer is not liable for personal injuries and material damages which result from improper use.
1. Safety Information
•
Read and understand all safety precautions and operating instructions contained in this manual.
•
Always wear eye protection when performing a compression test.
•
Do not exceed the maximum rating of the tester; 300 psi (20 bar) (2,000 kPa)
•
Prior to testing, set the gearbox to neutral on all vehicles or machinery having a standard transmission, or park for
automatic transmissions.
•
Prior to engaging ignition, ensure that the fuel supply is disabled using manufacturer's recommended method.
•
Make sure that all connections are secure prior to testing.
•
Take precautions to avoid contact with hot engine surfaces.
TO AVOID PERSONAL INJURY AND/OR VEHICLE DAMAGE:
While some precautions are specified in this manual, and should be noted to avoid personal injury or vehicle
damage, it is not possible for these cautions to cover all conceivable ways in which service or testing might be
done, or all possible hazardous consequences of each way, nor could Lincoln possibly know or investigate all
such ways. It is therefore the responsibility of anyone using this manual or any other Mityvac product, to satisfy
him or herself completely that neither personal safety nor vehicle safety will be jeopardized by the service methods
selected. Any such injury or damage is entirely the user's responsibility. This device is not to be used in any manner
on the human body.
2. Content of delivery
1x Manometer digital 0-20 Bar:
1x Manometer analogue 0-200 PSI:
1x Adaptor pipe with made coupling:
1x Adaptor pipe with made coupling:
1x Adaptor pipe with made coupling:
1x Adaptor bush L = 64 mm, dim. 21:
1x Adaptor bush L = 42 mm, dim. 18:
1x Adaptor bush L = 42 mm, dim. 18:
1x Coupling with ID 1/2" for air stop function for use with adaptor pipe
1x Valve and 'o' ring assortment
!
With compression coupling range in PSI, BAR or KPA
M14 x 1,25 thread and M18 x 1,5 thread
M18 x 1,5
M14 x 1,25 long thread
M14 x 1,25 short thread and M18 x 1,5 short thread
M14 x 1,25 IG x M18 x 1,5 AG
M14 x 1,25 IG x M12 x 1,25 AG
M14 x 1,25 IG x M10 x 1,0 AG