Electrical connections-Indoor units
Before starting installation, decide on the posi-
tion of the indoor and outdoor units, taking into
account the minimum space required around the
units.
• Install the indoor unit in the room to be air
conditioned, avoid to installing it in corridors or
communal areas.
• Install the indoor unit at a height of at least 2.5
m from the ground.
Installation of the mounting plate
1.
By using a level, put the mounting plate in
a perfect square position vertically and hori-
zontally.
2.
Drill 32 mm deep holes in the wall to fix the
plate.
3.
Insert the plastic anchors into the hole.
4.
Fix the mounting plate by using the provided
tapping screws.
5.
Check that the mounting plate is correctly
fixed.
Drilling a hole in the wall for the piping
1.
Decide where to drill the hole in the wall for
the piping (if necessary) according to the po-
sition of the mounting plate.
2.
The hole must slope downward towards the
exterior.
3.
Install a flexible flange through the hole in the
wall to keep the latter intact and clean.
Note: The shape of the mounting
plate may be different from the one
above, but the installation method is
similar.
53