1 Instructions for use Ubbink BioPressure 10000
Dear Customer,
we congratulate you on the purchase of a product from the high-quality Ubbink BioBalance pond filter series.
With these instructions for use, you receive important information which is useful for the assembly, commissioning and maintenance of your BioPressure pressure filter. Please read
these instructions for use prior to installation of the filter, and familiarise yourself with the device. It is essential that you observe the safety guidelnes for correct and safe use. Please
store these instructions for use carefully!
Scope of delivery
1 Pressure filter BioPressure 10000 with integrated UV-C device
1 Universal hose nozzle 40-32-25-19mm, transparent
2 Universal hose nozzle 40-32-25-19mm, black
3 Sealing rings 1 ½"
1 Threaded ring with sealing cap (glass)
1 Instructions for use

Technical data

Article No.
Filter contents
Filter medium
Pressure load
UV-C lamp
Mains voltage /frequency
Cable length
UV-C power after approx. 5,000 hrs.
Article No. for replacement UV-C quartz glass
Article No. for UV-C replacement lamp
Max. pond content
Hose connections
Recommended reference values for pump
Pond 8000 litres
Pond 9000 litres
Pond 10000 litres
Symbols & setting options
Water inlet from the pump to the filter
Water outlet from the filter into the pond
Water outlet in cleaning operation
"Filter operation" function switch
"Cleaning operation" function switch

Safety guidelines

WARNING:
UV radiation is hazardous to the eyes and skin. The UV-C lamp may not be operated if it has been taken out of the device housing!
CAUTION:
This unit contains a UV-C lamp! Inadvertent use of the device or damage to the housing can cause the leakage of hazardous UV-C radiation. Even
low doses of UV-C radiation can cause damage to the eyes and skin.
• The power supply must accord with the product specifications. Do not connect the UV-C device if the power supply does not fulfil the specified regulations! You can receive further
information from your local, authorised electrician.
• The power circuit for the UV-C device must be secured via a protection switch (residual current or RCD) with a rated residual current of max. 30 mA.
• Prior to each intervention (installation, maintenance, etc.), the UV-C device must be disconnected from the mains!
• The pressure filter incl. the UV-C device may not under any circumstances be put into use under water and must be installed next to the pond so that the risk of flooding is excluded.
• The installation of the pressure filter must take place at a distance of more than 2 m and the power connection at a distance of more than 3.5 m to the pond or water basin.
1355410
15 litres
Special multi-level filter mat
Max. 0,49 bar
PL-S 11 W
230 VAC / 50 Hz
4.5 m
85%
1358730
1355112
10,000 litres
25 mm
4500-5000 l/h
5000-7000 l/h
7000-10000 l/h