1 - TECHNICAL DATA
Power:
Autonomy:
Autonomy from the flat battery (Symbol
Type of action, disconnection and device:
Software:
Rated impulse voltage:
Type of output:
G
F
Wire section at relay terminals:
Input for phone programmer:
B
Wire section at phone programmer terminals:
Type of insulation:
Protection class:
N° of programmable indices on the ring of the clock:
Minimum programmable time with
Pollution:
Scale of adjustment temperature via knobs:
-
t
Comfort:
-
t
Economy (energy saving):
Temperature limit (max t. set lock):
Anti-freeze temperature (
t
Temperature setting accuracy:
Scale of ambient temperature display:
Room temperature reading tolerance:
Operating temperature range:
Storage temperature limits:
Temperature gradient:
Type of temperature adjustment:
Clock precision:
CE Mark reference standard:
14
2 alkaline Penlight batteries 1.5 V type AA LR6
2 years
lighting up):
1 month
1 / BU / Electronic
Class A
4 kV
relay with changeover contact NO / COM / NC - Voltage-free - max 5(3)A / 250Vac
0.75 ÷ 2.5 mm
for NO contact, voltage free
0.5 ÷ 1.5 mm
class II
IP 30
48
key (tappet)
:
½ h
Normal
+5 ÷ +30 °C (default +20 °C) / +41 ÷ +86 °F (default +68 °F)
+5 ÷ +30 °C (default +17 °C) / +41 ÷ +86 °F (default +62,6 °F)
Step 0,1°C / 0 ,1 °F
):
+5 °C / 41 °F (fixed not adjustable)
± 0,1 °C / ± 0,1 °F
0 ÷ +50 °C / +32 ÷ +122 °F
± 0,5 °C / ± 0,9 °F
0 ÷ +50 °C / +32 ÷ +122 °F
-20 ÷ +65 °C
max 1K/ 15 min.
ON-OFF operation with differential settable on 0.3 - 0.5 - 0.7 - 0.9 °C
Proportional operation with settable time cycles of 7-10-15-20 minutes
± 1 sec/day
LVD and EMC EN60730-2-7
(DURACELL or ENERGIZER batteries recommended)
2
2
/ -4 ÷ +149 °F
EN60730-2-9