Generator Features; Air Filter - Powermate PM0133250 Manuel De L'opérateur

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

A. Control Panel
NOTE: Total power drawn from all receptacles must not exceed
the nameplate ratings.
B.
120 V, 20 Ampere Receptacle
20 amps of current may be drawn from the receptacle,
provided it is not limited by the circuit protector size. Total
power drawn must be kept within nameplate ratings.
C. 120 Volt, 30 Ampere Twistlock Receptacle
Maximum full load current may be drawn from this
receptacle, provided it is the only receptacle used. Total
current must be limited to the nameplate rating. If other
receptacles are used at the same time, total power used must be kept
within nameplate ratings.
D. L5-30P to TT-30R RV Adapter
This adapter converts from the 120 Volt, 30 Amp
Twistlock Receptacle to a 120 Volt RV Plug.
E.
Receptacle Covers
F.
Circuit Protectors
The receptacles are protected by an AC circuit protector. If the
generator is overloaded or an external short circuit occurs, the circuit
protector will trip. If this occurs, disconnect all electrical loads and
try to determine the cause of the problem before attempting to use the
generator again. If overloading causes the circuit protector to trip,
reduce the load. NOTE: Continuous tripping of the circuit
protector may cause damage to generator or equipment. The
circuit protector may be reset by pushing the button of the protector.
G. Ground Terminal
H. Engine On/Off Switch
I.
Tank Clamping Knob
J.
208 CC OHV Engine
P
S
G
H
L
O
K
English

GENERATOR FEATURES

GENERATOR FEATURES
Q
R
B
F
C
A
E
12
K. Recoil Starter
L.
Engine Choke Lever
M. Oil Filler Cap
N. Oil Drain Plug
O. Air Filter
P.
Fuel Tank
Standard 20 or 30 pound capacity DOT LP Gas tank with Type
1, right hand Acme threads (not supplied with generator).
Q. Fuel Shut-Off Valve
Valve is on the fuel tank (not supplied with generator).
R. Fuel Regulator (under shroud)
S.
Multimeter
• When the generator is started, the voltage value is shown first.
• Press and release the mode button to toggle between Voltage,
Frequency, Total Hour Meter and Run/Maintenance
Timer.
• Voltage (V) displays the operating voltage of the generator.
• Frequency (F) displays the frequency in hertz at which the
generator is running.
• The Run/Maintenance Timer displays the time in hours and
minutes each time the generator is ran. The run timer resets
to 00:00 when the generator is shut off. Built into this run
timer is a maintenance reminder. When the new generator is
ran for 25 hours, the meter will display P25. This is to
remind you to change the oil after the initial 25 hours of run
time.
• When the Run/Maintenance Timer displays P50, it is
reminding you to clean the air filter.
• When the Run/Maintenance Timer displays P100, it is
reminding you to clean the air filter and change the oil.
N
J
I
M
Customer Hotline 1-800-445-1805

Publicité

Table des Matières
loading

Table des Matières