Parameter
C01
Door input (0 de-activated; 1 activated)
C02
Door open polarity
C03
Door open alarm delay
C04
Activates buzzer (0 de-activated; 1 activated)
C05
Buzzer duration at the end of quick cooling cycle
Temperature difference in the first phase of needle insertion
C06
test (0 = test excluded)
Duration of the second phase of needle insertion test (0=test
C07
excluded)
Activates condenser probe
C08
0 = no probe
1 = probe
C09
Compressor stop delay due to door opening
C10
Control pressure alarm detection time
C11
High pressare digital input polarity
C12
Resistances starting SetPoint
R01
Compressor start/stop hysteresis
R02
Min. interval between 2 compressor starting
R03
Compressor start delay from card activation
R04
Compressor Duty-Cycle time with faulty room probe in storing
R05
Compressor ON time faulty room in pos. storing
R06
Compressor ON time with faulty room in neg. storing
R07
Needle min. temperature for starting quick cooling
R08
Compressor block temperature
R09
Compressor Protection function activation time
R10
Pulse duration
R11
Pause between pulses
R12
Number of pulses
R13
Temperature at the end of the Cooling cycle
F01
Evaporator fans activation hysteresis
F02
Condenser fans activation hysteresis
F03
Evaporator fans activation SetPoint
F04
Condenser fans activation SetPoint
Evaporator fans during defrost
F05
0 = fans OFF; 1 = fans ON
Condenser fans during defrost
F06
0 = fans OFF; 1 = fans ON
F07
Fans stop time after defrost
F08
Condenser fans stop delay
Evaporator fans control during quick cooling:
F09
0 = fans always ON
1 = fans thermostated by evaporator temperature
Evaporator fans control during storing:
F10
0 = fans in parallel with the compressor
1 = fans thermostated by evaporator temperature
F11
Evaporator fans block temperature
PR1
Sampling time
CF1
Evaporator fan min. speed
CF2
Evaporator fan min. speed selectable in a quick cooling cycle
N
S
T
A
L
L
A
N
S
T
A
L
L
A
N
S
T
A
L
L
A
Description
CONFIGURATION
VENTILATION SPEED (P.W.M.)
T
I
O
N
M
A
N
T
I
O
N
M
A
T
I
O
N
M
A
Default
(BCF...)
ADJUSTMENT
24 hour
FANS
PRINT
U
A
L
-
N
U
A
L
-
N
U
A
L
-
Default
min
(BC...)
1
1
0
0
2 min
2 min
0 min
1
1
10 sec
10 sec
13°F
45°F
56 sec
56 sec
1
1
30 sec
30 sec
0 sec
5 sec
5 sec
0 sec
0
0
23°F
23°F
14°F
5°F
38°F
0°F
2 min
2 min
0 min
0 sec
0 sec
0 sec
10 min
10 min
0 min
3 min
3 min
0 min
8 min
8 min
0 min
158°F
158°F
32°F
194°F
194°F
32°F
24 hour
0 hour
2 sec
2 sec
1 sec
8 sec
4 sec
1 sec
3
3
-13°F
-13°F
-58°F
4°F
36°F
0°F
4°F
36°F
0°F
41°F
41°F
-58°F
59°F
59°F
-58°F
0
0
0
0
1 min
1 min
0 min
30 sec
30 sec
0 sec
0
0
0
0
158°F
158°F
32°F
10 min
1 min
10 min
30
20
50
50
MAX
0
1
0
1
60 min
0
1
0
600 sec
0
140°F
0
600 sec
0
1
60 sec
60 sec
0
1
68°F
36°F
30 min
300 sec
90 min
90 min
90 min
194°F
212°F
240 hour
10 sec
10 sec
1
20
50°F
36°F
36°F
122°F
122°F
0
1
0
1
30 min
300 sec
0
1
0
1
194°F
60 min
0
100
0
100
33