businesses or for equivalent purposes.
4. Technical data
Motor power supply: ............................... 18 V DC
Maximum number of operations per minute: .. 20
Staple width: ........................................... 5.7 mm
Staple length: ..................................... 16-22 mm
Staple thickness: ........................................ 1 mm
Nail length: ......................................... 15-32 mm
Nail thickness: ............................................ 1 mm
Weight: .......................................................2.1 kg
Danger!
Sound and vibration
Sound and vibration values were measured in
accordance with EN 60745.
L
sound pressure level ..................... 84,1 dB(A)
pA
K
uncertainty ............................................. 3 dB
pA
L
sound power level ....................... 95,1 dB(A)
WA
K
uncertainty ............................................. 3 dB
WA
Wear ear-muff s.
The impact of noise can cause damage to hea-
ring.
Total vibration values (vector sum of three direc-
tions) determined in accordance with EN 60745.
Vibration emission value a
K uncertainty = 1.5 m/s
The stated vibration emission levels and stated
noise emission values were measured in ac-
cordance with a set of standardized criteria and
can be used to compare one power tool with
another.
The stated vibration emission levels and stated
noise emission values can also be used to make
an initial assessment of exposure.
Warning:
The vibration and noise emission levels may vary
from the level specifi ed during actual use, depen-
ding on the way in which the power tool is used,
especially the type of workpiece it is used for.
Anl_TE_CN_18_Li_SPK13.indb 16
Anl_TE_CN_18_Li_SPK13.indb 16
= 2.879 m/s
2
h
2
- 16 -
GB
Keep the noise emissions and vibrations to a
minimum.
•
Only use appliances which are in perfect wor-
king order.
•
Service and clean the appliance regularly.
•
Adapt your working style to suit the appliance.
•
Do not overload the appliance.
•
Have the appliance serviced whenever ne-
cessary.
•
Switch the appliance off when it is not in use.
Caution!
Residual risks
Even if you use this electric power tool in
accordance with instructions, certain resi-
dual risks cannot be rules out. The following
hazards may arise in connection with the
equipment's construction and layout:
1. Lung damage if no suitable protective dust
mask is used.
2. Damage to hearing if no suitable ear protec-
tion is used.
3. Health damage caused by hand-arm vib-
rations if the equipment is used over a pro-
longed period or is not properly guided and
maintained.
Danger!
The electric power tool generates an electro-
magnetic fi eld during operation. Under certain
circumstances this fi eld may actively or passively
impede medical implants. To reduce the risk of
serious or fatal injuries, we recommend persons
with medical implants to consult their doctor and
the manufacturer of the medical implant prior to
using the equipment.
5. Before using the equipment
Warning!
Always remove the rechargeable battery
before starting any inspection or adjusting
work.
Warning:
Wear the necessary protective clothing, in
particular safety goggles, when working with
the cordless nailer.
Pay attention to the safety regulations.
•
Each time before starting work, check that the
magazine cover is securely fastened (Fig. 1/
Item 3). Clean the equipment thoroughly and
09.09.2021 12:06:05