Télécharger Imprimer la page

Sunforce Wind Power Notice D'utilisation page 6

Publicité

Les langues disponibles

Les langues disponibles

Check Step:
1. In normal situations, the green LED should be illuminated once connected to a battery.
2. The RED LED should be illuminated once the manual break is turned on. To test this please
toggle the switch to the off and then the red LED should no longer be illuminated.
Consequently there will an audible clicking that will indicate that the relay switch is functioning
properly.
3. If the wind turbine is in rotation in high speed, the charging LED will illuminate.
Notification:
1. Multiple function MPPT chargers will charge a battery and may also be connected to a DC
to AC inverter or DC load. The current output passed by the terminal will also be
managed by the charger.
2.
Loose connections can cause a large voltage drop to occur which may result in damage to
the wires and insulation. Always adhere to correct polarity. Double check before you
activate your system. Damage caused by reverse polarity is not covered under the
warranty The wire between wind turbine and Multiple Function MPPT Charger should be
#8 AWG. When connecting the RED (positive, (+)) terminal to the 12 volt power source's
6

Publicité

loading

Produits Connexes pour Sunforce Wind Power