Product Description; Circuit Diagram; Connection Terminals; Approvals And Markings - DOLD SAFEMASTER C UG 6960 Traduction De La Notice Originale

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Safety Technique
SAFEMASTER C
Multifunctional Safety Timer
UG 6960

Product Description

The multifunction safety timer UG 6960 provides protection of men and
machines by enabling and disabling a safety circuit. This is done by the
adjusted time delay function. Simply select 1 out of 5 delay functions
with a rotary switch – ready. The adjusted time is safe over the complete
setting range. The UG 6960 is available for different safety functions.
It has safe delayed and instantaneous contacts.

Circuit Diagram

13
14
23
24
A1+
A2
ST1
38
S11
S12
S21
S22
13
23
47
+
K1
K3
K1/K2
K2
K4
14
24
38
48
RES
GND
ST2
68
58
47
48
57

Connection Terminals

Terminal designation
A1 +
A2
13, 14, 23, 24
47, 48, 57, 58
38, 68
GND
S11, S21
S12, S22, ST1, ST2, RES
All technical data in this list relate to the state at the moment of edition. We reserve the right for
technical improvements and changes at any time.
57
+
K3/K4
58
68
M10506_a
Signal description
DC 24 V
0 V
Forcibly guided NO contacts for
release circuit
Forcibly guided NO contacts for
delayed contacts
Semiconductor monitoring output
Reference potential for
Semiconductor monitoring output
Control output
Control input
Your Advantage
• Various delay functions adjustable at device:
- Release delay
- Release delay retriggerable
- On delay
- Fleeting on make / break
- Delay function settable via potentiometer
• Various safety functions defined:
- E-Stop
- Safety gate
- Two-hand control
- Safety mat / Safety edge
- Exclusive or contacts
- Light curtain
• Manual or auto start
• Instantaneous contact and safety delayed contacts
• Protection against manipulation by sealable transparent cover
Features
• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508 and IEC/EN 61511
• Acc. to EN 50156-1 for furnaces
• Line fault detection on On-button:
• Manual restart or automatic restart
• With or without cross fault monitoring
• 2-channel
• Forcibly guided output contacts
• Output: 2 NO instantaneous contact and 2 NO contacts delayed
• 1 semiconductor output for instantaneous contacts
1 semiconductor output for delayed contacts
• LED indicator for operation, safety function, time delay and failure
• As option with pluggable terminal blocks for easy exchange of devices
- with screw terminals
- or with cage clamp terminals
• Width: 22.5 mm

Approvals and Markings

Application

Protect people and machines in applications with e-stop buttons, safety
gates, light curtains with selftesting (Type 4) acc. to IEC/EN 61 496-1,
2-hand controls for presses as well as other production machinery with
dangerous closing action (Type III C to EN 574) and for safety mats, safety
edges and tape switches with a max. switching current of 15 mA.

Indicators

Green LED ON:
Red LED ERR:
Green LED K1/K2:
Green LED K3/K4:
17
Canada / USA
On, when supply connected
On, at internal error
flashes at external error
On, when relay K1 and K2 energized
(instantaneous contact)
Flashes at external errors
(see flashing codes)
On, when relay K3 and K4 energized
(delayed contacts)
Flashes during time delay