DESCRIPTION OF THE CONTROL UNIT

The CITY7 control unit is an innovative V2 product guaranteeing
safety and reliability for swing gate automation.
The CITY7 design has been aimed at creating a product which
adapts to suit all needs, thus obtaining an extremely versatile
control unit satisfying all the necessary requirements for a
functional and efficient installation.
• 230V - 50Hz or 120V - 60Hz power supplies, depending on
the model, for 2 single phase motors (700W global).
• Input for keyswitch or push-button.
• Input for safety photocell.
• Input for safety edge, capable of handling standard edges
with switch normally closed and conductive rubber edges with
nominal resistance of 8.2 kOhms.
• Pre-opening safety device testing.
• Dip-switch programmable operational logic.
• Adjustment of motor power and operation time by means of
a trimmer.
• Quick plug-in connector for inserting a Mr1 series receiver.
• LED monitoring of inputs.
• Courtesy light output.
• IP55 casing.
TECHNICAL
SPECIFICATIONS
Power supply
Max motors load
Max accessories load 24V
Working temperature
Protection fuse
Dimensions
Weight
Protection
ADJUSTMENT OF THE POWER AND
OPERATIONAL TIMES
The power and operating times may be adjusted by means of 4
trimmers located on the control unit:
POWER:
motor power.
WORK:
motor operating time (2 - 120 seconds).
PLEASE NOTE: it is recommended that operating times be
set with the slow down function disabled (DIP 5 OFF).
WARNING: the adjustment of times has to be made
when the gate is still
PAUSE:
pause time before automatic re-closure
(2 - 150 seconds).
DELAY:
time delay between the two gate leaves
(0 - 90 seconds).
230V models
120V models
230V / 50Hz
120V / 60Hz
700W
700W
3W
3W
-20 ÷ +60 °C
-20 ÷ +60 °C
F1 = 5A delayed F1 = 8A delayed
170 x 185 x 70 mm
800 g
IP55
CONTROL UNIT INDICATORS (LEDS)
The highlighted boxes indicate the state of the LEDs when the
gate is resting.
LED
ON
START
START input closed
IN2
START P. input closed START P. input open
STOP
STOP input closed
PHOTO
PHOTO input closed
EDGE input closed
(edge not pressed)
EDGE
EDGE input closed
(edge pressed)
Edge NO pressed:
8K2 between EDGE
input and common (-)
Control unit
mains
powered-up
Accessory power
overload
supply overload

CABLE GLAND ASSEMBLY

The casing can accept 4 cable glands in the special easy-break
housings.
The type of cable gland is indicated in the figure.
PLEASE NOTE:
• Remove the electronic circuit board before drill the casing.
• Drill the container using a suitably sized cutter,
according to the dimensions of the cable gland.
• Fix the cable glands using the special nuts.
32
OFF
START input open
STOP input open
PHOTO input open
Standard edge
EDGE input open (edge
pressed)
Resistive rubber edge
EDGE input open
(fault)
Control unit NOT powered-up
Accessory power supply within
normal operational limits