7.
Complete Installation Kit Assembly
7.1
Remove the cover plate (see instructions for the fitting).
Spare parts
7.2
Remove the screws (a).
7.3
Remove the solenoid-valve cartridge (b).
7.4
Use a flat nose pliers to pull the existing filter (c) out.
7.5
Continue with
Retrofitting thermal disinfection
7.6
Remove the screws (d).
7.7
Unscrew the plug (e).
☞
Use an M8 screw to pull out the plug via the centre thread.
7.8
Insert the new filter.
☞
Important!
Ensure correct installation position. The rib of the filter must not lie on the flow-
through hole.
7.9
Reassemble in the reverse order.
8.
Installation, Shower
8.1
Remove the stainless steel housing (see instructions for shower panel).
☞
Never let the stainless steel housing hang by the connecting hoses.
Spare parts
8.2
Disconnect the line connection between the solenoid valve cartridge and the
connection terminal.
8.3
Remove the screws (a).
8.4
Remove the solenoid-valve cartridge (b).
8.5
Use a flat nose pliers to pull the existing filter (c) out.
8.6
Continue with
Retrofitting thermal disinfection
8.7
Remove the screws (d).
8.8
Unscrew the plug (e).
☞
Use an M8 screw to pull out the plug via the centre thread.
8.9
Insert the new filter.
☞
Important!
Ensure correct installation position. The rib of the filter must not lie on the flow-
through hole.
8.10 Reassemble in the reverse order.
4
Instruction Step
7.8.
Instruction Step
8.9.