OTC 1857 Mode D'emploi page 3

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

1. Determine the best location for the press. Choose an isolated
or shielded area with a smooth, solid, level floor.
2. Remove the shipping banding securing the press frame to
the shipping pallet. Remove all cartons and set aside.
3. Using an appropriate crane or hoist, stand the press frame
upright and attach an angle foot to the outside of each lower
upright. Place the frame on the floor and disconnect the hoist.
4. Remove the lock ring and spring securing the winch handle
to the winch axle. Flip the winch handle 180° and reassemble
the ring and spring.
5. Open the boxes found on the shipping pallet. Mount the
pump mounting bracket to the right-hand upright using two
hex head cap screws and nuts. See Figure 1.
6. Place the pump on the mounting bracket. Thread four cap
screws through the bottom of the bracket and into the pump
reservoir. See Figure 1.
CAUTION: Use a high-grade, non-hardening pipe sealant to
seal all hydraulic connections. If using Teflon tape, apply
one or two threads back to prevent the tape from becoming
pinched or broken off inside the hydraulic system. Loose
pieces of tape can travel through a hydraulic system and
obstruct the flow of oil damaging the system.
7. Clean the threads on the hydraulic hose(s) and fittings.
Assemble the hose(s) to the pump.
8. Gauge mounting options:
The gauge can be mounted to the gauge port on the pump
with a 45° elbow as shown in Figure 2 and 3.
Or the gauge can be mounted at the cylinder by using a
tee adapter between the swivel fitting and hose. If using a
double-acting cylinder, install the gauge in the top swivel
fitting as shown in Figure 4. When installing a gauge at the
cylinder, install a pipe plug in the pump's gauge port.
2
Item
Part
No.
No.
Qty.
Description
10648
1
1
45° Elbow Fitting
(included w/ 52434 single-acting cylinder)
10648
2
45° Elbow Fitting
(included w/ 51683 double-acting cylinder)
52434A
2
1
Single-acting Cylinder
51683A
1
Double-acting Cylinder
1858 & 1858-1P)
Pressure gauge can
be installed here on a
double-acting cylinder.
1
Figure 4
(Used on 1857)
(Used on
Assembly
2
1
Item
Part
No.
1
50931
2
10204
3
10052
10798
4
6
5
Item
No.
1
2
3
4
5
6
7
Figure 3
(For 1857 press)
Item
Part
No.
No.
Qty.
1
4008
1
2
10492
1
3
303840
1
No.
Qty.
Description
1
Pump Mounting Bracket
2
Hex Nut (3/8-16)
2
Hex Hd. Cap Screw (.375-16 x 1.25" lg.)
4
Hex Hd. Cap Screw (.5-20 x .75" lg.)
Figure 1
7
4
3
Part
No.
Qty.
Description
61217
1
Electric Pump (Used on 1858)
4064
1
Electric Pump (Used on 1858-1P)
10645
1
45° Street Elbow
10492
1
Pressure Gauge
13828
1
Straight Elbow
10647
1
Elbow Fitting (90° x .375 NPTF)
10474
1
Elbow Fitting (90° x .375 NPTF)
9769
1
Hydraulic Hose (10 ft.; contains 2)
Figure 2
(For 1858 and 1858-1P presses)
1
Description
Hand Pump
Gauge
Hydraulic Hose (10 foot)
SP04519269 Rev A
3
4
1
2
2
3
Page 3

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

18581858-1p

Table des Matières