Key to symbols on the energizer
Fence earth terminal. Connect the fence earth terminal to the
energizer earth system.
Fence earth monitor terminal (12000i, X12i, 412i, 6000i, X6i
and 406i only). Connect the fence earth monitor terminal to a
separate earth rod. See
Fence half voltage terminal. For use in areas with poor
Bi-polar installation
earthing, see
a limit of 5 kV fence voltage is desirable (e.g. where fire risk is
present or where there is a risk of someone touching the
Reducing the fence voltage output
fence), see
Connect the fence half voltage terminal to the fence.
Fence full voltage terminal. Connect the fence full voltage
terminal to the fence.
Risk of electric shock! This energizer should be opened or
repaired only by qualified personnel.
Read full instructions before use.
This symbol on the product or its packaging indicates that this
product must not be disposed of with other waste. Instead, it
is your responsibility to dispose of your waste equipment by
handing it over to a designated collection point for the
recycling of waste electrical and electronic equipment. The
separate collection and recycling of your waste equipment at
the time of disposal will help conserve natural resources and
ensure that it is recycled in a manner that protects human
health and the environment. For more information about
where you can drop off your waste equipment for recycling,
please contact your local city recycling office or the dealer from
whom you purchased the product.
The energizer has a double-insulated construction.
Warning!
- USA and Canada - To reduce the risk of electric shock, the
energizer's power adaptor may have a polarized plug (one blade is
wider than the other). This plug will fit in a polarized outlet one
way. If the plug does not fit fully in the outlet, reverse the plug. If
it still does not fit, contact a qualified electrician to install the
proper outlet. Do not change the plug in any way.
- Switch the energizer off before installation or performing any work
on the fence.
- Read all the safety considerations carefully. See
considerations
on page 9.
- Check your installation to ensure that it complies with all local
safety regulations.
- Do not connect simultaneously to a fence and to any other device
such as a cattle trainer or a poultry trainer. Otherwise, lightning
striking your fence will be conducted to all other devices.
- Use only the mains/line power adaptor or battery leads supplied
with this energizer or a genuine replacement part.
Note:
-
This product has been designed for use with electric animal fences.
-
Keep these instructions in a handy location.
Installation
Read all of the safety instructions in this manual and any relevant
government, regional and local safety standards before installing the
energizer.
2
Earth monitoring
on page 4.
on page 7 or in areas where
on page 7.
Safety
Selecting a site for the installation
Follow these guidelines when selecting a site for your installation.
Select a site where:
a good earth can be obtained
the energizer earth system will be at least 10 m (33') from other
earth systems (e.g. telephone, mains power or the earth system of
another energizer)
children and animals cannot interfere with the installation
Make sure the energizer is installed:
adjacent to the electric fence
preferably in the middle of the electric fence system
close to a mains/line power outlet (if using a mains/line supply to
power the energizer)
at least 1 m (3') away from and not directly above the battery (if
using a battery to power the energizer)
If your installation is outdoors, also make sure that it is:
on firm ground away from flooding
inside a protective fence, if required.
Using the power adaptor and battery leads
The energizer is supplied with a power adaptor (for connection to
mains/line power) and a set of battery leads (for connection to a
battery). Before connecting a power adaptor or battery leads, ensure
the energizer's selector switch is set to Off
To use the power adaptor:
1
Connect the power adaptor to the Power input socket on the rear
of the energizer.
2
Connect the power adaptor to a suitable mains/line power socket,
ensuring there is 25 mm (1") of clear space around the power
adaptor.
To remove the power adaptor:
1
Disconnect the power adaptor from the mains/line power.
2
Pull on the white connector to remove the power adaptor plug
from the Power input socket on the rear of the energizer.
To use the battery leads:
1
Insert the battery lead into the Power input socket on the rear of
the energizer.
2
Connect the energizer to the battery using the battery leads
supplied. Attach the red clip to the positive (+) terminal of the
battery, and the black clip to its negative (-) terminal.
Note:
If the energizer is to be used as part of a permanent outdoor
installation such as a solar installation, the battery lead clips should be
replaced by permanent battery connectors.
To remove the battery leads:
1
Remove the clips from the battery terminals.
2
Hold the battery lead by the rubber sleeve at the end of the wire.
Pull firmly to remove the connector from the Power input socket
on the rear of the energizer.
Installing the energizer indoors
The energizer must be installed indoors, (under cover) when being
powered by mains/line power.
Warning!
- Do not use a mains/line power extension lead.
- Allow 25 mm (1") of clear space around the power adaptor.
.