WARNING! BREATHING HAZARD. Always wear an
appropriate NIOSH-approved respirator and personal
protective equipment when removing or replacing
filters, or when cleaning the Syclone Sentry X4.
Before each use
Inspect the electrical cord for damage, and do not use the unit
if you find any fraying, cuts, etc. Contact your local Aramsco
distributor for service.
As Needed
Clean housing and impeller. Clean impeller assembly with
pressurized air and/or with a soft cloth. Do not apply liquids to
the impeller assembly. The housing may be cleaned with a
mild solution of detergent and warm water. Ensure housing is
completely dry before reassembling.
Remediation applications
Wear NIOSH-approved protective gear when changing
TROUBLESHOOTING
PROBLEM
Unit does not operate
Circuit breaker trips
Change filter light
illuminated
For any problems not described here, please contact your local Aramsco distributor for assistance.
Model
Air movement
Static pressure (H
O)
2
Circuit maximum
Dimensions (D × W × H)
Weight
Amps
Volts
Frequency
Power
Duct size
Filter system
Controls
Power cord length
Construction
Safety
Specifications are subject to change without notice. Some values
may be approximate.
07-02365B CFM400-ARM
CAUSE
1.
No power to machine
2.
Switch not turned on
3.
No power at supply outlet
4.
Circuit breaker tripped
1.
Power cord is damaged
2.
Amp draw from power outlet is
too high.
Airflow is restricted at the inlet,
prefilter, and/or HEPA filter.
Syclone Sentry X4 (CFM400-ARM)
405 CFM
2.63 in.
Four additional units for a total of five.
22.9 × 17.7 × 21.7 in. 58.2 × 45.0 × 55.1
cm
29 lbs. | 13.2 kg
2.16A
115V
60 Hz
215 W
12 in. (inlet and outlet)
One prefilter and one HEPA filter.
On/Off switch
16 ft. | 4.9 m
Rotomolded polyethylene housing
ETL tested to UL standards
filters.
Change filters after every remediation job.
Change HEPA filter when the filter indicator light (Fig. D)
comes on.
Dispose of used filters according to local regulations.
Replace both the prefilter and HEPA filter to prevent
cross-contamination.
Vacuum and wipe off the unit thoroughly after each job
before removing it from the containment area to avoid
cross-contamination. Pay particular attention to the area
around the air intake. Let the unit dry before installing
clean filters.
For more information on remediation best practices, For more
information about using the Syclone Sentry X4 for restoration
and remediation projects, consult the IICRC at 360-693-5675
or visit www.IICRC.org.
SOLUTION
1.
Plug in the unit; check power at outlet
2.
Turn on the switch
3.
Reset supply circuit breaker
4.
Reset circuit breaker
1.
Replace power cord. Contact your Aramsco
distributor.
2.
Reduce the amount of equipment plugged into the
power outlet.
1.
Check for inlet restrictions.
2.
Remove pre-filter and switch unit on. If light turns
off, replace prefilter.
3.
If light is still on without the pre-filter then replace
the HEPA filter.
WARNING: This product may expose you to
chemicals, including lead and phthalates, known to the
State of California to cause cancer, birth defects, or other
reproductive harm. For more information, go to
P65Warnings.ca.gov
FOR PARTS AND SERVICE CALL YOUR LOCAL ARAMSCO
DISTRIBUTOR OR ARAMSCO AT 800-767-6933. ARI Holding
Corp. 1480 Grandview Ave., Paulsboro, NJ 08066
4
Aramsco