Dlx & Dlx/B Vft/Mb Microcontroller Dosing Pumps; Pump Controls; Typical Installation; Accessories - Etatron DLX-VFT/MB Serie Notice D'installation, Emploi Et Entretien

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

DLX - DLX/B VFT/MB
7.0 - DLX & DLX/B VFT/MB MICROCONTROLLER DOSING PUMPS
The pump is equipped with a modern microcontroller allowing design of a extremely compact and reliable
electronic device.
7.1 - PUMP CONTROLS (Fig. 12)
1 - Increasing values button
2 - ON/STAND BY button
3 - Decreasing values button
4 - "green" LED 1:N function
5 - "green" LED 1XN (M) function/water meter
6 - "green" LED 1XN function/ manual mode
7 - "red" LED injection pulse flashing
8 - "green/red" LED pump fed/stand by
9 - 7 segment display
10 - function selection button
7.2 - TYPICAL INSTALLATION (Fig.13)
A Injection valve
B
Power supply
C Filter
D Level probe
I
Chemical tank
K Pulse emitting water meter
S Process tank

7.3 - ACCESSORIES

1 flexible PVC suction hose,
transparent crystal type, length 2 m;
1 semirigid polyethylene hose, white, 2 m;
1 injection valve 3/8 BSP m;
1 filter;
1 instructions/operating booklet.

7.4 - LEVEL CONTROL

The dosing pump is supplied with level
control setting. When the chemical tank is
empty, on display
(9) it
pump goes in stand by. The level control has
5 seconds of delay.
appears AL1 and the
28