Télécharger Imprimer la page

Stid ARCS Notice D'installation page 2

Lecteurs évolutifs
Masquer les pouces Voir aussi pour ARCS:

Publicité

Les langues disponibles

Les langues disponibles

ARCS / ARCS Blue
Upgradable readers
Installation instructions
ARCS-X/PH5
X:
ARCS-X/BT1
ARCS-XC/PH5
ARCS-XC/BT1
Use an AC/DC power supply type LPS, Limited Power Source (as per IEC EN 60950-1 Ed2) or type ES1, PS1 (according to IEC EN 62368-1) for the main
supply.
Main power supply:
Range: +7 Vdc to +28 Vdc
Max. consumption at 12 Vdc:
ARCS-A/PH5: 140 mA ARCS-C/PH5: 210 mA ARCS-E/PH5: 320 mA ARCS-I/BF5: 170 mA
ARCS-B/PH5: 170 mA ARCS-D/PH5: 290 mA ARCS-F/PH5: 360 mA ARCS-J/BF5: 200 mA
ARCS-A/BT1: 150 mA ARCS-C/BT1: 220 mA ARCS-E/BT1: 330 mA ARCS-I/BT2: 180 mA
ARCS-B/BT1: 180 mA ARCS-D/BT1: 300 mA ARCS-F/BT1: 370 mA ARCS-J/BT2: 210 mA
Communication:
RS485 (L+ & L-) / TTL (Wiegand / Clock and Data)
Connection:
Removable connectors 1x10 pins and 1x2 pins, thread 0.19685 inch OR cable.
Protection:
IP65, excluding connectors
ASSR-1218-003E: 60 V output withstand voltage / 0.2A current rating / low on-resistance 1 Ω typical for AC/DC
Static relay:
Screw terminal output: Use a multi-conductor shielded twisted pair cable.
Max. length RS485:
Wiegand / Clock & Data:
Cable output (cable supplied): TRANXALARM - 14x0.22mm2 - lg 3,05m.
The operating mode for the Buzzer and LED 1 and 2 can be programmed by a configuration card (R3x & S3x) or controlled by the remote system with a 0 Vdc
respectively on the "Led 1", "Led 2" and "Buzzer" inputs of the reader's connector or controlled by the communication protocol of the reader (W3x).
Tearing is detected by an accelerometer. When the reader is wrenched, the switch output (connector J2) provides an O/C contact to indicate the tearing of
reader.
for R/S 31: the wrenching signal will be emitted on the "Data/Data1" line. This function is configurable via a configuration card.
for R/S 33: the reader will perform the operations configured with the configuration card.
for W33: the reader will perform the operations configured with the SSCP protocol.
Caution: switch on the reader when it is in its final position to initialize the accelerometer in the correct position.
STid reserves the right to make change without notice, for the purpose of product improvement.
Screw terminal output product references
A: Standard
D: Standard + Biometrics
B: Keypad
E: Keypad + Biometrics
C: Touch screen
F: Touch screen + Biometrics
J6: Antenna connector
J7: Keypad connector
J9: Biometric connector
J14: Display connector
J2: O/C contact
Cable output product references
X:
A: Standard
B: Keypad
C: Touch screen
J6: Antenna connector
J7: Keypad connector
J9: Biometric connector
J14: Display connector
J15: Output cable
Typical: 12 Vdc
328.1 ft at 9600 baud
1 pair AWG24 – 98.4 ft max / 2 pairs AWG24 – 196.9 ft max / 3 pairs AWG24 – 328.1 ft max
1 pair AWG20 – 164.0 ft max / 2 pairs AWG20 – 328.1 ft max
© STid - 20 PA des Pradeaux FR13850 Gréasque - NI1114C06- Page 1 sur 15 - Ed. 04/04/2019
ARCS / ARCS Blue
Lecteurs évolutifs
Notice d'installation
ARCS-X/BF5
ARCS-X/BT2
Connector
J4
1
2
3
4
5
6
7
8
9
10
D: Standard + Biometrics
E: Keypad + Biometrics
F: Touch screen + Biometrics
1
Dark blue
2
Pink
3
Orange
4
White
5
Yellow
6
Red
7
Blue
8
Grey
9
Green
10
White Brown
11
White purple
12
Brown
Power supply characteristics
Characteristics
Recommended cables
Buzzer / LED
Anti-tearing
ARCS / ARCS Blue
Lectores escalables
Procedimiento de instalación
conforme con NOM-024 -SCFI-2013
X:
I: Standard + 125 kHz module
J: Keypad + 125 kHz module
Type
Wiegand
Clock & Data
RS485
0 Vdc
+Vcc (+7 Vdc to +28 Vdc)
D0
Code
NC
D1
Data
NC
Clock
Clock
NC
L+
NC
NC
NC
NC
Led 1
Led 2
Buzzer
Type
Wiegand
Clock & Data
J15
SW2
SW1
Led 2
Buzzer
Clock
Clock
+Vcc (+7 Vdc to +28 Vdc)
D1
Data
D0
Code
Led 1
NC
NC
NC
NC
0 Vdc
US
FR
ES
L-
RS485
NC
NC
NC
L+
L-

Publicité

loading

Ce manuel est également adapté pour:

Arcs blueArcs-x/ph5Arcs-x/bt1Arcs-x/bf5Arcs-x/bt2