English
Sensor tube and
process connection
Material
Sensor tube diameter
R½ (½" BSPT)
G½A, G¾A
M18 × 1,5
M20 × 1,5
½" NPT
Connection
A
A/F
Without
18.5
Ø18
G½, R½
20.5
22.0
M18, M20
20.5
22.0
½" NPT
20,5
22.0
G½ nipple
40,0
27.0
G¾ nipple
44,5
32.0
G1 nipple
47,5
36.0
G½ union
51.0
27.0
G¾ union
51.0
32.0
Response time (time constant)
Sensor
Sensor
Insert
diameter
tip
Ø6 mm
Fast
Standard
8 mm
Fast
Standard
Standard
Yes
10 mm
Fast
Standard
Standard
Yes
www.baumer.com
Stainless steel, AISI 316L
Ø6, Ø8 or Ø10 mm
G½A
G½
G¾A
G¾
G1
L
25...3.000
25...3.000
Connection
25...3.000
G½
25...3.000
R½
25...3.000
M18, M20
25...3.000
½" NPT
25...3.000
G½, G¾,
25...3.000
G1 nipple
G½, G¾ union
25...3.000
0,5
Liquid
Air
0,4 m/sec
3 m/sec
0 m/sec
<1,5 sec
<21,4 sec <135,6 sec
<6,1 sec
<27,2 sec <137,8 sec
<1,5 sec
<33,6 sec <181,0 sec
<7,6 sec
<47,7 sec <200,9 sec
<13,6 sec <51,1 sec <253,1 sec
<1,5 sec
<46,8 sec <238,9 sec
<11,1 sec <57,8 sec <270,6 sec
<28,1 sec <67,0 sec <271,1 sec
Operating instructions: 11119033 02
CombiTemp™ TCR6
Operating instructions
Sensor element specifications (DIN/EN/IEC 60751)
Sensor element
Accuracy (sensor element)
Single element
Double element
Connection
Sensor element
Accuracy (sensor element)
Connection
DIN form B
head
71
Norm
DIN 3852 form A
ISO 7/1
ISO 261
ANSI/ASME
ISO 228/1
ISO 228/1
°C
Air
100
1
80
2
3
60
40
1: Sensor without thermowell (Embedded sensor)
20
2: Sensor with thermowell, with thermal compound
3: Sensor with thermowell, without thermal compound
0
1
2
3
Note: When a thermowell is used, the time delay increases.
The delay is the time duration for the sensor to reflect the correct
temperature after a temperature change in the media.
Pt100
Class B
±(0,3 + 0,005×t)°C
- 1/3 B
±1/3 × (0,3 + 0,005×t)°C
- 1/6 B
±1/6 × (0,3 + 0,005×t)°C
Class A
±(0,15 + 0,002×t)°C
1 × Pt100
2 × Pt100
2-wire or 4-wire
Pt1000
Class B ±1/3 × (0,3 + 0,005×t)°C
2-wire
76
Sensor tip
Standard
Fast response
4
5
6
7
8
9
10 Minutes
M20
Ø4 × 20 mm
Page 2 / 12