– ALWAYS install the heater so that it is not
directly exposed to water spray, rain, dripping
water, or wind.
– Use heater in accordance with all local codes.
In the absence of local codes, refer to The
National Fuel Code, ANSI Z223.1.
For use with propane (LP)
WARNING
gas only.
– This heater is shipped from the factory for
use with propane (LP) gas only. Do not
convert to any other gas. Installation must
conform to local codes, or in their absence,
with the standard for the Storage and
Handling of Liquefied Petroleum Gases
ANSI/NFPA 58 and the Natural Gas and
Propane Installation Code CSA B149.1.
– Gas supply connections should be checked
by using a 50/50 soap and water solution.
Never use a flame to check for gas leaks.
RISK OF FIRE! ALWAYS LOCATE HEATER ON A STABLE AND LEVEL
WARNING
SURFACE! (SEE FIGURE 1)
Figure 1
Model #
BTU
Fuel Consumption (Lbs./hr)
Heat Settings
Maximum Operating Hours
Required Cylinder Lbs.
Fuel Type
Heating Area (Ft.
)
2
© 2018 Pinnacle Climate Technologies, Inc.
NEVER LEAVE HEATER UNATTENDED WHILE BURNING,
CONNECTED TO A POWER SOURCE, OR WHILE
CONNECTED TO A FUEL SOURCE
SAFETY INFORMATION (CONT.)
– Locate LP cylinder at least 6 feet (10 ft. in
– Use only the regulator and hose assembly
SPECIFICATIONS
REM-80V-LPC-B
60,000 / 70,000 / 80,000
2.8 / 3.2 / 3.7
3
36
100
Propane
1,800
Specifications subject to change without notice.
4
The hose assembly shall be
WARNING
pro tected from traffic, building
material and contact with hot surfaces both
during use and while in storage.
Canada) from the heater, and do not direct
heater discharge towards the LP cylinder
unless it is at least 20 feet from the heater.
provided with this heater. Inspect the
regulator/hose assembly prior to each use of
the heater. If there is excessive abrasion or
wear, or if the hose is cut, replace it with the
proper assembly shown in the parts list, prior
to using the heater.
Minimum and Maximum Inlet Pressure
REM-80V-LPC-B
Min.
Max.
Convection Heater User's Manual
REM-200V-LPC-B
5 PSI
Bottle Pressure
REM-200V-LPC-B
70,000 – 200,000
3.2 / 9.3
Variable
31
100
Propane
5,000