DANGER
CARBON MONOXIDE POISONING MAY LEAD TO DEATH!
– Risk of indoor air pollution and Carbon
Monoxide Poisoning. Use heater only in
well ventilated areas.
– Refer to Safety Information on pages 2-3
for information about Carbon Monoxide
Poisoning.
– ALWAYS provide a fresh air opening in the heated
space of at least three square feet (2,800 sq. cm) for
each 100,000 BTU / Hr. of heater output. Provide a larger
opening if more heaters are being used.
Always disconnect the heater from the LP
cylinder before putting the heater into storage.
If for any reason the heater is to be stored
indoors, the tank MUST be disconnected from
the LP cylinder, and the cylinder stored outdoors
in a well-ventilated area, out of the reach of
children, and in accordance with the Standard
for Storage and Handling of Petroleum Gases,
ANSI/NFPA 58 - latest edition and Natural Gas
and Propane Installation Code, CSA B149.1. The
plastic valve plug or valve cover supplied with
the cylinder must be re-installed on the valve to
protect the fitting from damage.
© 2018 Pinnacle Climate Technologies, Inc.
NEVER LEAVE HEATER UNATTENDED WHILE BURNING,
CONNECTED TO A POWER SOURCE, OR WHILE
CONNECTED TO A FUEL SOURCE
VENTILATION
STORAGE / MAINTENANCE
NOTE: Installation and repair of this heater
should be done by a qualified service person.
ALWAYS be sure to follow proper maintenance
procedures. This should include cleaning the
inside of the heater once a month and checking
the spark gap at least once a heating season. Re-
gap the terminals to 0.195" (4.9 mm).
10
Minimum Ventilation Opening Needed
REM-80V-LPC-B
2.4 ft.
2
2220 cm
2
Not for use in residential
DANGER
living areas or in non-
adequately ventilated enclosed spaces.
Never store an LP cylinder
DANGER
inside of a building or near
any other gas or oil burning appliances.
Convection Heater User's Manual
REM-200V-LPC-B
6.0 ft.
2
5570 cm
2