Maintenance (Continued)

rePlaCeMeNt PartS

Use only genuine
Campbell Hausfeld
service parts. Tool performance, safety and
durability could be reduced if improper parts
are used. When ordering replacement parts,
specify by part number.

aSSeMbly ProCedure For SealS

When repairing a nailer, the internal parts
must be cleaned and lubricated. Parker
O-lube or equivalent must be used on
all o-rings. Each o-ring must be coated
with O-lube before assembling. A small
amount of oil must be used on all moving

Troubleshooting Guide

Stop using nailer immediately if any of the following problems occur. Serious personal injury could result.
Any repairs or replacements must be done by a Qualified Service Person or Authorized Service Center.
SYMPTOM
Lack of power; slow to cycle.
Shooting no fastener or
intermittent feeding
Fastener jammed in tool
surfaces and pivots. After reassembling,
a few drops of 30W non-detergent oil or
equivalent, must be added through the air
line before testing.

teCHNICal ServICe

For information regarding the operation
or repair of this product, please call
1-800-543-6400.
CAUSe
1.
Tool is too dry
2.
Air pressure is low
3.
Exhaust is blocked
1.
Damaged pusher spring
2.
Wrong size fastener is being used
3.
Magazine or wear plate is dirty
1.
Driver channel is worn
2.
Driver is broken or worn
3.
Fasteners are bent
SOLUTION
1.
Add lubricant
2.
Check air supply equipment
3.
Clean exhaust
1.
Replace spring
2.
Use standard fasteners
3.
Clean magazine and nose
1.
Replace wear plate
2.
Replace driver
3.
Use standard fasteners