EN – Installer information
Electrical
connection
100–240V AC
8
ELECTRICAL CONNECTION 100–240VAC
NB! Wiring of 100–240 V AC must be performed
by a qualified electrician.
Norte auto:
100–240 V AC 50 / 60Hz
Factory-set for continuous basic ventilation, auto-
matic forcing at elevated humidity levels and under
the influence of changes in light.
Possibility to start / stop via manual switch T.
Norte switch-operated, with run-on time:
(Can be combined with backdraught shutter)
100–240 V AC 50/60 Hz
Must be selected via Pax App.
Start/stop via manual switch T.
Norte humidity-controlled:
(Can be combined with backdraught shutter)
100–240 V AC 50/60 Hz
Must be selected via Pax App.
Basic setting, automatic start/stop at changes in
humidity level.
Possibility to start / stop via manual switch T.
Norte heat distributor:
100–240 V AC 50/60Hz
Must be selected via Pax App.
Basic settings, starts at 25 ° C, stops at 22 ° C.
Norte switch-operated on / off
(Can be combined with backdraft shutter)
100–240 V AC 50 / 60Hz
Must be selected via Pax App.
Start / stop via manual switch L.
NB! The integrated all-pole switch S only
functions at 100–240 V AC wiring.
T
T
L
100-240VAC
N
S
+
_
12VDC
User and installation instructions
M