Warranty Conditions - PAX Norte Informations Pour Les Utilisateurs

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 35
Requirements for functionality via app
Versions of the operating system is updated
continuously, for information go to:
www.pax.se
Fault indication:
Red LED on the fan indicates power failure when
the calendar function has been activated.
Reset by syncing the app with the fan.
Activate the app: (T)
You have to have a code to activate the app. The
code is unique to each fan. Enter the code or scan
it using your phone. Your unique code is on the
back of the user guide and on the right leg of the
motor unit (Figure T).
Learn more about all the possibilities with our
app at www.pax.se
Cleaning
(U-V)
Strong solvents must not be used on the fan.
The fan must not be dipped in or sprayed with water.
For the fan to continue to function and maintain its
capacity, it must be cleaned at least twice a year,
more often if necessary.
– Before cleaning, switch off the power to the fan.
For a 100–240 V connection, use the all-pole
switch in Figure U by switching it off (0). For a 12 V
connection, turn off the power at the appropriate
external switch.
– Detach the motor unit by grasping it as shown
User and installation guide
in (Figure V). Pry off the motor unit by leveraging
against the cover with your knuckles. Ensure that
you have the motor unit in a secure grip so you
do not drop it when it is detached.
– Clean the opening, the duct and the motor unit
with a damp cloth (if necessary, use a mild deter-
gent).
– The impeller is cleaned directly on the motor (NB
the impeller cannot be detached).
– If the fan has an external backdraught shutter,
the shutter blades should be cleaned gently. The
backdraught shutter must be located in the duct
between the fan and the outer wall.
– Replace the motor unit in the frame member.
Recycling
Discarded fans should be submitted as electronic
waste to a recycling centre.
Safe Water Installation
This product conforms to industry regulations for
Safe Water Installation.
The supplier guarantees that the product will
function correctly if industry regulations and the
product's instructions are complied with. All holes
for screws must be made as shown in Figures X
and Y.
For wooden wet room walls (Figure X), drill only
through the coating and waterproofing.
NB: Never drill through any plywood.
Fill the entire hole with age-resistant sealing
compound. Use plumbing screws. Screw through
the plywood or into the studwork.
For concrete wet room walls (Figure Y), drill the
appropriate hole depth for the plug.
Fill the hole with age-resistant sealing compound.
Push the plug into the hole.
Fill the entire plug with age-resistant sealing
compound.
Use plumbing screws and screw the product in
place.

Warranty conditions

The Pax Norte has a five-year warranty for defects
in manufacturing and materials. The warranty is
subject to the following conditions:
– The fan must have been installed by a qualified
electrician.
– The fan must have been assembled and installed
in accordance with the advice and instructions in
(X-Y)
this user and installation guide.
– The fan must be cleaned regularly in accordance
with the advice and instructions in this user and
installation guide.
– The fan must be installed and used indoors.
– The fan must not be used in exposed environ–
ments (for example in industrial or other en-
vironments where there is a risk of the fan being
exposed to solvents, a high dust density, gases,
etc.).
EN – For the user