6.3.2. Electromagnetic compatibility and susceptibility

Compliant with IEC 61326-1 for emissions and immunity in industrial use.

6.3.3. Protection from electric shocks

Type A clamp with double insulation or reinforced insulation in the grip part in
normal use, and double insulation or reinforced insulation between the primary
and the secondary output and the terminations part of the USB power supply and
the BNC output.
Maximum service voltage per EN61010-2-032
- 300V in installations of category III and degree of pollution 2.
- 600V in installations of category II and degree of pollution 2.

6.3.4. Variations in the nominal of the use

Quantity of influence
USB supply voltage
Relative humidity
Temperature on
measurement
Settling time
Pass band (without
filter)
Position of the cable
Repeatability of the
measurement
Common mode
rejection
Rejection of an external
current at 50Hz (
External magnetic field
(spatial position) (
High-frequency
electromagnetic field,
10V/m
between 650MHz and
750MHz
1
(
) Conductor outside the jaws and parallel to the position of a conductor in the jaws.
2
(
) Measurement made after demagnetization of the clamp. For this purpose, set to AC, I = 0, gradually
increase the value to I = 40A. Gradually reduce the value to I = 0.
Influence
5 VDC ±5%
or storage battery voltage
between 20% and
100% charge
10% at 90% RH
-10°C to +45°C
45°C to +50°C
upon start of operation
DC to 1kHz
to 100kHz
to 500kHz
to 1MHz
DC to 100Hz
10 open./clos.
50Hz
400Hz
near air gap
jaws
1
)
grip
DC (Earth's)
2
)
value of the current
Typical
±0.12%/°C
±0.22%/°C
-0.2dB
-0.5dB
-1.5dB
mean : 0.3%
30dB
34dB
40dB
±0.3mV or
±30mA
1.2A
26
Oscilloscope clamp
Maximum
0
none
0.1% of Is
10 s
-0.5dB
±1.5%
>90dB or 0.003%
>80dB or 0.01%
±1mV or
±100mA
1.5A max
1%
-1dB
-3dB

Publicité