5
Troubleshooting
ERROR MESSAGES
The following error codes may be shown on the display:
Error code
SH
HL
SL
FH
(With warning sound)
IMPORTANT INFORMATION ON PROBLEMS
A. Loss of air
Inflatable SPAs can lose air after a certain period of time due to their design, especially when exposed to direct sunlight and/or high tempera-
tures. This is a normal phenomenon and does not mean that the SPA has a damaged area where air leaks.
Step 1
Check the tightness of the air valve screw connection (black/grey). This valve has a double function, i.e. to inflate and deflate air..
Note: After inflating the SPA, it is possible that the lower screw connection has loosened during the inflation process. After inflation, the follo-
wing must therefore be done to prevent air leaks:
Air inlet (black):
Air outlet (grey):
Step 2
If further air escapes after step 1, perform the following test to locate the affected area.
- Spray soapy water onto the UPVC body of the SPA
- Bubbles will form on the leaky area
Manual SPA 2/4/6 2020_2.indd 57
Manual SPA 2/4/6 2020_2.indd 57
Cause
Circuit board or temperature sensor malfunction
Temperature sensor malfunction
Filter pump malfunction
Filtering and heating have been in operation for 72
hours. Both the filter pump and the heating are not
ready for operation before replacement of the filter
cartridge
screw the screw cap back on hand-tight
tighten the lower part of the screw connection hand-tight
Solution
Perform a reset (switch off and switch back on after 10 minutes).
Replace the display and/or the motor block
Perform a reset (switch off and switch back on after 10 minutes).
Replace the motor block
Perform a reset (switch off and switch back on after 10 minutes).
Replace the motor block
Replace the filter cartridge and press the HEATER button to restart the filtering
and heating
30.09.20 17:21
30.09.20 17:21